ASME B31.3-2016 <br /> provided the owner approves and the vessel test pres- 345.7.3 Examination for Leaks. The examination for <br /> sure is not less than 77% of the piping test pressure leaks required by para. 345.2.2(a) shall be conducted <br /> calculated in accordance with para. 345.4.2(b). while the system is at operating pressure. It is permissi- <br /> ble to omit examination for leaks of joints and connec- <br /> 345.5 Pneumatic Leak Test tions previously tested in accordance with this Code. <br /> 345.5.1 Precautions. Pneumatic testing involves <br /> the hazard of released energy stored in compressed gas. 345.8 Sensitive Leak Test <br /> Particular care must therefore be taken to minimize the The test shall be the Bubble Test — Direct Pressure <br /> chance of brittle failure during a pneumatic leak test. Technique in accordance with the BPV Code,Section V, <br /> Test temperature is important in this regard and must Article 10,Appendix I or another leak test method that <br /> be considered when the designer chooses the material has a demonstrated sensitivity not less than <br /> of construction. See para. 345.2.2(c) and Appendix F, 10-3 std ml/s under test conditions. <br /> paras. F323.4 and F345.5.1. When the Bubble Test — Direct Pressure Technique <br /> 345.5.2 Pressure Relief Device. A pressure relief is used <br /> device shall be provided, having a set pressure not (a) the test pressure shall be at least the lesser of <br /> higher than the test pressure plus the lesser of 345 kPa 105 kPa (15 psi) gage or 25% of the design pressure. <br /> (50 psi) or 10% of the test pressure. (b) the pressure shall be gradually increased until a <br /> gage pressure equal to the lesser of one-half the test <br /> 345.5.3 Test Fluid. The gas used as test fluid,if not pressure or 170 kPa (25 psi) is attained, at which time <br /> air, shall be nonflammable and nontoxic. a preliminary check shall be made. Then the pressure <br /> (16) 345.5.4 Test Pressure. The test pressure shall be shall be gradually increased in steps until the test pres- <br /> not less than 1.1 times the design pressure and shall not sure is reached,the pressure being held long enough at <br /> exceed the lesser of each step to equalize piping strains. <br /> (a) 1.33 times the design pressure <br /> (b) the pressure that would exceed 90%of the pressure 345.9 Alternative Leak Test <br /> described in para. 345.2.1(a) The following procedures and leak test method maybe <br /> 345.5.5 Procedure. The pressure shall be gradually used only under the conditions stated in para. 345.1(c). <br /> increased until a gage pressure that is the lesser of one- 345.9.1 Examination of Welds. Welds, including <br /> half the test pressure or 170 kPa (25 psi) is attained, at those used in the manufacture of welded pipe and fit- <br /> which time a preliminary check shall be made,including tings, that have not been subjected to hydrostatic or <br /> examination of joints in accordance with para.341.4.1(a). pneumatic leak tests in accordance with this Code,shall <br /> Thereafter,the pressure shall be gradually increased in be examined as follows: <br /> steps until the test pressure is reached,holding the pres- <br /> sure at each step long enough to equalize piping strains. (a) Circumferential, longitudinal, and spiral (helical <br /> seam) groove welds shall be 100% radiographed in <br /> The pressure shall then be reduced to the design pressure <br /> accordance with para. 344.5 or 100% ultrasonically <br /> before examining for leakage in accordance with <br /> para. 345.2.2(a). examined in accordance with para. 344.6. <br /> (b) All welds,including structural attachment welds, <br /> 345.6 Hydrostatic-Pneumatic Leak Test not covered in (a) above, shall be examined using the <br /> If a combination hydrostatic-pneumatic leak test is liquid penetrant method (para. 344.4) or, for magnetic <br /> used, the requirements of para. 345.5 shall be met,and materials, the magnetic particle method (para. 344.3). <br /> the pressure in the liquid filled part of the piping shall 345.9.2 Flexibility Analysis. A flexibility analysis <br /> not exceed the limits stated in para. 345.4.2. of the piping system shall have been made in accordance <br /> 345.7 Initial Service Leak Test with the requirements of para. 319.4.2 (b),if applicable, <br /> or (c) and (d). <br /> This test is applicable only to piping in Category D <br /> Fluid Service, at the owner's option. See para. 345.1(a). 345.9.3 Test Method. The system shall be subjected <br /> to a sensitive leak test in accordance with para. 345.8. <br /> 345.7.1 Test Fluid. The test fluid is the service fluid. <br /> 345.7.2 Procedure. During or prior to initial opera- <br /> tion, the pressure shall be gradually increased in steps 346 RECORDS <br /> until the operating pressure is reached,holding the pres- 346.2 Responsibility <br /> sure at each step long enough to equalize piping strains. <br /> A preliminary check shall be made as described in It is the responsibility of the piping designer,the manu- <br /> para. 345.5.5 if the service fluid is a gas or vapor. facturer,the fabricator,and the erector,as applicable,to <br />