Laserfiche WebLink
5EDCAD+ CULVERT SIZING UTILITY <br />ORCHARD VALLEY CULVERT "5" 10-YEAR <br />Design Discharge = 10.000 cfs <br />Entrance Loss Coefficient = 0.9 <br />• Pipe Length <br />Pipe Slope 60.000 <br />3.000 feet <br />Planning's n 0.024 <br />Maximum Headwater = 2.500 feet <br />Tailwater Depth = 0.000 feet <br />Smallest Diameter Required to Pass Flow is 18 inches <br />PERFORMANCE CURVES: <br />Diameter: 15 inches <br />Headwater Discharge Flow <br />(ft) <br />------------- (cfs) <br />------------ Control <br />------------------------ Type <br />--------- <br />0.25 0.47 Outlet (Subcritical) 1 <br />0.50 0.95 Inlet (Supercritical) 3 <br />0.75 1.72 Inlet (Supercritical) 3 <br />1.00 2.63 Inlet (Supercritical) 3 <br />1.25 3.67 Inlet (Supercritical) 3 <br />1.50 4.71 Inlet (Supercritical) 4 <br />1.75 5.61 Inlet 5 <br />2.00 6.18 Inlet 5 <br />2.25 6.51 Outlet 6 <br />2.50 6.84 Outlet 6 <br /> <br /> Diameter: 18 inches <br />Headwater Discharge Flow <br />(ft) <br />------------- (cfs) <br />------------ Control <br />------------------------ Type <br />--------- <br />0.25 0.54 Outlet (Subcritical) 2 <br />0.50 1.12 Inlet (Supercritical) 3 <br />0.75 2.04 Inlet (Supercritical) 3 <br />1.00 3.15 inlet (Supercritical) 3 <br />1.25 4.40 Inlet (Supercritical) 3 <br />1.50 5.78 Inlet (Supercritical) 3 <br />1.75 7.22 Inlet (Supercritical) 3 <br />2.00 8.42 Inlet 5 <br />2.25 9.50 Inlet 5 <br />2.50 10.26 Inlet 5 <br /> <br />Diameter: 21 inches <br />Headwater Discharge Flow <br />(ft) <br />------------- (cfs) <br />------------ Contr <br />------- ol <br />----- Type <br /> <br />0.25 <br />0.59 - <br />Outlet ----- <br />------ <br />(Subcritical) --------- <br />2 <br />0.50 1.32 Inlet (Supercritical) 3 <br />0.75 2.40 Inlet (Supercritical) 3 <br />1.00 3.67 Inlet (Supercritical) 3 <br />1.25 5.12 Inlet (Supercritical) 3 <br />1.50 6.74 Inlet (Supercritical) 3 <br />1.75 8.49 Inlet (Supercritical) 3 <br />2.00 10.31 Inlet (Supercritical) 4 <br />2.25 11.90 Inlet 5 <br />C-7~ <br />