Laserfiche WebLink
Cz Laboratories, Inc. • • • - • <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 - • • <br /> ACZ Project ID: L64296 <br /> ACZ ID WORKNUM PARAMETER METHOD QUAL DESCRIPTION <br /> L64296-01 WG514571 `AII Compounds' M8021B/8015D GC/PID/FID Q6 Sample was received above recommended temperature. <br /> Benzene M8021 B/8015D GC/PID/FID Q9 Insufficient sample received to meet method QC <br /> requirements. <br /> Ethylbenzene M8021B/8015D GC/PID/FID Q9 Insufficient sample received to meet method QC <br /> requirements. <br /> m p Xylene M8021 B/8015D GC/PID/FID Q9 Insufficient sample received to meet method QC <br /> requirements. <br /> o Xylene M8021 B/8015D GC/PID/FID Q9 Insufficient sample received to meet method QC <br /> requirements. <br /> Toluene M8021 B/8015D GC/PID/FID Q9 Insufficient sample received to meet method QC <br /> requirements. <br /> TVH C6 to C10 M8021 B/8015D GC/PID/FID Q9 Insufficient sample received to meet method QC <br /> requirements. <br /> WG514799 'AII Compounds' M8015D GC/FID 06 Sample was received above recommended temperature. <br /> TPH C10 to C28 M8015D GC/FID R1 RPD exceeded the method or laboratory acceptance limit. <br /> See Case Narrative. <br /> M8015D GC/FID RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG514572 'AII Compounds' M826OC/D GUMS Q6 Sample was received above recommended temperature. <br /> Methyl Tart Butyl Ether M8260C/D GC/MS Q9 Insufficient sample received to meet method QC <br /> requirements. <br /> L64296-02 WG514571 'AII Compounds' M8021B/8015D GC/PID/FID Q6 Sample was received above recommended temperature. <br /> Benzene M8021B/8015D GC/PID/FID Q9 Insufficient sample received to meet method QC <br /> requirements. <br /> Ethylbenzene M8021 B/8015D GC/PID/FID Q9 Insufficient sample received to meet method QC <br /> requirements. <br /> m p Xylene M8021 B/8015D GC/PID/FID Q9 Insufficient sample received to meet method QC <br /> requirements. <br /> o Xylene M8021 13/8015D GC/PID/FID Q9 Insufficient sample received to meet method QC <br /> requirements. <br /> Toluene M8021 B/8015D GC/PID/FID Q9 Insufficient sample received to meet method QC <br /> requirements. <br /> TVH C6 to C10 M8021B/8015D GC/PID/FID Q9 Insufficient sample received to meet method QC <br /> requirements. <br /> WG514799 'AII Compounds' M8015D GC/FID Q6 Sample was received above recommended temperature. <br /> TPH C10 to C28 M8015D GC/FID R1 RPD exceeded the method or laboratory acceptance limit. <br /> See Case Narrative. <br /> M8015D GC/FID RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG514572 'AII Compounds" M8260C/D GC/MS Q6 Sample was received above recommended temperature. <br /> Methyl Tart Butyl Ether M8260C/D GC/MS Q9 Insufficient sample received to meet method QC <br /> requirements. <br /> L64296-03 WG514571 'AII Compounds' M8021 B/8015D GC/PID/FID Q6 Sample was received above recommended temperature. <br /> REPAD.15.06.05.01 <br /> L64296-2102241528 Page 11 of 15 <br />