My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2021-05-12_REVISION - M2012032
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M2012032
>
2021-05-12_REVISION - M2012032
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2025 6:24:47 AM
Creation date
5/17/2021 6:08:33 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M2012032
IBM Index Class Name
REVISION
Doc Date
5/12/2021
Doc Name
Adequacy Review Response
From
Ouray Silver Mines, Inc.
To
DRMS
Email Name
LJW
Media Type
D
Archive
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
242
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
QJRAY SaLvm MINES <br /> concrete foundation <br /> C-8 tank failure 9,200 Instantaneous I Cannot Leave Site and vertical curbs <br /> 3.4 Containment and Diversionary Structures (40 CFR 112.7(c)) <br /> Secondary containment and capacities are shown in Table 2.1. Methods of secondary <br /> containment at this facility include a combination of structures, berms, site topography and spill <br /> response (sorbents). <br /> Other containment in transfer locations and other parts of the facility: <br /> • Drip pans. Fill ports for all AST's are equipped with drip pans to contain minor leakage <br /> from piping/hose connection; <br /> • Absorbent material. Spill cleanup kits are located as shown on the Plan map. The spill <br /> kits are situated within close proximity oil/fuel storage and handling areas for rapid <br /> deployment should a spill occur; and <br /> • Unloading Pad. The concentrator delivery/transfer area is a concrete pad sloped into the <br /> center to contain a spill should it occur. <br /> 3.5 Practicality of Secondary Containment(40 CFR 112.7(d)) <br /> OSMI management has determined that secondary containment is practicable at this facility. <br /> 3.6 Inspections,Tests and Record (40 CFR 112.7(e)) <br /> As required by the SPCC rule, OSMI performs all inspections,tests and evaluations listed in <br /> Table 3.2 which tabulates the various inspections and tests performed at the facility.The <br /> inspections are further described in this section and in the respective sections that describe <br /> various parts of the facility. <br /> Spill Prevention Control and Countermeasure Plan 15 1 P a g e <br />
The URL can be used to link to this page