My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2021-03-25_REVISION - M2012032
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M2012032
>
2021-03-25_REVISION - M2012032
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2024 8:03:50 AM
Creation date
3/29/2021 9:02:04 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M2012032
IBM Index Class Name
Revision
Doc Date
3/25/2021
Doc Name
Decision Date Extension Request
From
Ouray Silver Mines Inc.
To
DRMS
Type & Sequence
TR12
Email Name
LJW
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ACZ Laboratories, Inc. • - - • - • <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 - • • <br /> ACZ Project ID: L64296 <br /> ♦ WORKNUM ♦♦ QUAL DESCRIPTION <br /> L64296-01 WG514571 *All Compounds* M8021B/8015D GC/PID/FID Q6 Sample was received above recommended temperature. <br /> Benzene M8021 B/8015D GC/PID/FID Q9 Insufficient sample received to meet method QC <br /> requirements. <br /> Ethylbenzene M8021 B/8015D GC/PID/FID Q9 Insufficient sample received to meet method QC <br /> requirements. <br /> m p Xylene M8021B/8015D GC/PID/FID Q9 Insufficient sample received to meet method QC <br /> requirements. <br /> o Xylene M8021 B/8015D GC/PID/FID Q9 Insufficient sample received to meet method QC <br /> requirements. <br /> Toluene M8021B/8015D GC/PID/FID Q9 Insufficient sample received to meet method QC <br /> requirements. <br /> TVH C6 to C10 M8021B/8015D GC/PID/FID 09 Insufficient sample received to meet method QC <br /> requirements. <br /> WG514799 *All Compounds* M8015D GC/FID Q6 Sample was received above recommended temperature. <br /> TPH C10 to C28 M8015D GC/FID R1 RPD exceeded the method or laboratory acceptance limit. <br /> See Case Narrative. <br /> M8015D GC/FID RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG514572 *All Compounds* M8260C/D GC/MS Q6 Sample was received above recommended temperature. <br /> Methyl Tart Butyl Ether M8260CID GC/MS Q9 Insufficient sample received to meet method QC <br /> requirements. <br /> L64296-02 WG514571 *All Compounds* M8021B/8015D GCIPID/FID Q6 Sample was received above recommended temperature. <br /> Benzene M8021B/8015D GCIPID/FID Q9 Insufficient sample received to meet method QC <br /> requirements. <br /> Ethylbenzene M8021B/8015D GCIPID/FID Q9 Insufficient sample received to meet method QC <br /> requirements. <br /> m p Xylene M8021B/8015D GC/PID/FID Q9 Insufficient sample received to meet method QC <br /> requirements. <br /> o Xylene M8021 B/8015D GC/PID/FID Q9 Insufficient sample received to meet method QC <br /> requirements. <br /> Toluene M8021 B/8015D GC/PID/FID Q9 Insufficient sample received to meet method QC <br /> requirements. <br /> TVH C6 to C10 M8021B/8015D GC/PIDIFID 09 Insufficient sample received to meet method QC <br /> requirements. <br /> WG514799 *All Compounds* M8015D GC/FID 06 Sample was received above recommended temperature. <br /> TPH C10 to C28 M8015D GC/FID R1 RPD exceeded the method or laboratory acceptance limit. <br /> See Case Narrative. <br /> M8015D GC/FID RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG514572 *All Compounds* M8260CID GC/MS Q6 Sample was received above recommended temperature. <br /> Methyl Tart Butyl Ether M8260C/D GUMS Q9 Insufficient sample received to meet method QC <br /> requirements. <br /> L64296-03 WG514571 *All Compounds* M8021B/8015D GC/PID/FID Q6 Sample was received above recommended temperature. <br /> REPAD.15.06.05.01 <br /> L64296-2102241528 Page 11 of 15 <br />
The URL can be used to link to this page
Your browser does not support the video tag.