slopes can be left in place with no modifications where they will be completely covered by stable fill <br /> slopes. Regarding the fill slopes, the summary report states that existing fill slopes and future <br /> constructed fill slopes can be graded to a final configuration as follows: <br /> • Bench Slope Angle of 26.5 degrees or 2H:1 V <br /> • Maximum Bench Height of 50 feet <br /> • Minimum Bench Width of 15 feet <br /> • Maximum Overall Slope Height of 150 feet <br /> A site visit was conducted on January 81h, 2021 during which visual verification was made of the <br /> continuity of slope conditions from what was included in the Kleinfelder Report to the present <br /> conditions. <br /> Sincerely, <br /> HDR <br /> �o kN\Mo"ry; <br /> • o <br /> 4 <br /> Andrew Little, PG PE NAL <br /> Project Geological Engineer <br />