Laserfiche WebLink
Subsidence Evaluation for the <br /> Exhibit 60E Southern Panels, Apache Rocks West, & Sunset Trail Mining Areas Page 18 <br /> Horizontal compressive strain ranges from-0.004 to-0.018 (-0.4 to-1.8 percent)where <br /> the extraction thickness equals 9 feet, and-0.007 to -0.028 (47 to -2.8 percent)where <br /> it equals 14 feet(Table 2). <br /> The E-seam panels E1 to E5 and B-seam panels B26 to B29 occur on top of one another, but are <br /> not stacked based on the current panel layout. However, to be conservative, the strain of the two <br /> seams is assumed to be additive. <br /> • For E-seam and B-seam panels, projected horizontal tensile strain ranges from 0.009 <br /> to 0.044 (0.9 to 4.4 percent) where the planned coal extraction thickness is 9 feet, and <br /> from 0.014 to 0.069 (1.4 to 6.9 percent) where the extraction thickness equals 14 feet. <br /> Horizontal compressive strain ranges from-0.009 to-0.047(49 to-4.7 percent)where <br /> the extraction thickness equals 9 feet, and-0.014 to -0.073 (-1.4 to -7.3 percent)where <br /> it equals 14 feet(Table 2). <br /> Apache Rocks West Mining Area: <br /> Maximum tensile and compressive horizontal strains are calculated,using the values obtained from <br /> the area of the West Elk Mine, and as projected in Figure 5 (Table 3). These values are believed <br /> to be conservative,based on Dunrud's annual observations in the Apache Rocks West mining area. <br /> • Panels EIO to E12: For these panels, projected horizontal tensile strain ranges from <br /> 0.007 to 0.028 (0.7 to 2.8 percent) where the planned coal extraction thickness is 10 <br /> feet, and from 0.009 to 0.039 (0.9 to 3.9 percent)where the extraction thickness equals <br /> 14 feet. <br /> Horizontal compressive strain ranges from-0.007 to-0.030(47 to-3.0 percent)where <br /> the extraction thickness equals 10 feet,and-0.009 to-0.042(49 to-4.2 percent)where <br /> it equals 14 feet(Table 3). <br /> • Panels B12 to B13-A: For these panels,projected horizontal tensile strain ranges from <br /> 0.007 to 0.018 (0.7 to 1.8 percent) where the planned coal extraction thickness is 12 <br /> feet. <br /> Horizontal compressive strain ranges from -0.007 to-0.019 (-0.7 to-1.9 percent)where <br /> the extraction thickness equals 12 feet. <br /> The E-seam panels E10 to E12 and B-seam panels B12 to 13A occur on top of one another, but <br /> are not stacked based on the current panel layout. However, to be conservative, the strain of the <br /> two seams is assumed to be additive. <br /> • For E-seam and B-seam panels, projected horizontal tensile strain ranges from 0.013 <br /> to 0.046 (1.3 to 4.6 percent)where the planned coal extraction thickness is 10 feet, and <br /> from 0.016 to 0.057 (1.6 to 5.7 percent) where the extraction thickness equals 14 feet. <br /> 831-032.912 Wright Water Engineers, Inc. <br /> December 2020 <br />