My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2020-11-05_REVISION - M1973021 (12)
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1973021
>
2020-11-05_REVISION - M1973021 (12)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2025 3:58:45 AM
Creation date
11/9/2020 2:21:52 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1973021
IBM Index Class Name
REVISION
Doc Date
11/5/2020
Doc Name Note
Part 1 of 9
Doc Name
Request For Amendment To Permit
From
Aggregate Industries-WCR Inc.
To
DRMS
Type & Sequence
AM7
Email Name
TC1
MAC
ECS
Media Type
D
Archive
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
238
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Table 7-5. Slope Stability Analyses Results: West Quarry Global and Local Stability <br /> Factor of Safety (FOS) <br /> Highwall Analysis Case <br /> SLOPE/W FLAC/Slope <br /> Global 2.01 1.57 <br /> Global w/ Sillimanitic Gneiss 1.52 1.29 <br /> West Highwall Local: 30 ft Bench at El. 7,000 1.30 <br /> (East Facing) Local: 40 ft Bench at El. 7,000 1.32 1.28 <br /> Local: 30 ft Bench at El. 6,650 <br /> Local: 60 ft Bench at El. 6,650 1.27 1.33 <br /> Global 4.30 4.44 <br /> East Highwall <br /> Global w/ Sillimanitic Gneiss 3.45 3.53 <br /> (West Facing) <br /> Local 1.70 2.40 <br /> Note: <br /> 1.) All future benches above El.7,000 ft have been modeled with a highwall height of 40 ft,width of <br /> 65 ft, and a face angle of 90°as this cell will be flatter than benches and highwalls below El. 7,000. <br /> The computed FOS above El. 7,000(up to El.7,320)is 1.57 that exceeds the State required FOS of <br /> 1.25 for global stability. <br /> The results show in Table 7-5 indicate adequate global stability, with FOS' ranging from <br /> 1.52 to 4.30 and 1.29 to 4.44 for SLOPE/W and FLAC/Slope, respectively (including <br /> variation with the highwall and the presence of Sillimanitic Gneiss). The analyses indicate <br /> the configuration does not meet minimum criteria if a 30-ft wide bench is included at El. <br /> 7,000 feet or El. 6,650 feet. A 40-foot minimum width for the top bench at El. 7,000 and a <br /> 60-foot minimum width for the intermediate bench at El. 6,650 feet is required to meet <br /> minimum State standard of FOS of 1.25 for the West Quarry West Highwall (East Facing). <br /> 39 <br /> Aggregate Industries—Morrison Quarry GEI Consultants, Inc. <br /> AM-07 Geotechnical Stability Exhibit November 2020 <br />
The URL can be used to link to this page
Your browser does not support the video tag.