Laserfiche WebLink
Emergency Spillway <br />10' <br />1 ONO Slo(0� ---------- pe _\ <br />Emergency Spillway <br />Not to Scale <br />Scale 1'1 = 30' <br />Contour Interval = 1 Ft. <br />q-7 <br />6355.00 <br />6354.00 <br />6353.00 <br />6352.00 <br />6351.00 <br />O 6350.00 <br />W 6349.00 <br />6348.00 <br />6347.00 <br />6346.00 <br />6345.00 <br />0.00 <br />Stage Storage Curve <br />Rail Loop Pond <br />0.50 <br />ELEV <br />Width <br />LENGTH <br />(ft) <br />(ft) <br />(ft) <br />6345.00 <br />N/A <br />N/A <br />6346.00 <br />N/A <br />N/A <br />6347.00 <br />N/A <br />N/A <br />6348.00 <br />N/A <br />N/A <br />6349.00 <br />N/A <br />N/A <br />6350.00 <br />N/A <br />N/A <br />6351.00 <br />N/A <br />N/A <br />6352.00 <br />N/A <br />N/A <br />6353.00 <br />N/A <br />N/A <br />6354.00 <br />N/A <br />N/A <br />6355.00 <br />N/A <br />N/A <br />1.00 <br />1.50 <br />2.00 <br />2.50 <br />Accumulative Storage (Acre -Ft) <br />Storage Volume Computations <br />AREA <br />AVG. <br />INTERVAL <br />STORAGE <br />ACC. <br />STAGE <br />(ac) <br />AREA <br />(ft) <br />(ac -ft) <br />STORAGE <br />INTERVAL <br />(ac) <br />(ac -ft) <br />(ft) <br />0.0141 <br />0.0569 <br />1.00 <br />0.0842 <br />0.0901 <br />1.00 <br />0.0997 <br />0.1111 <br />1.00 <br />0.1112 <br />0.2013 <br />2.00 <br />0.1224 <br />0.1327 <br />1.00 <br />0.1325 <br />0.3338 <br />3.00 <br />0.1429 <br />0.1549 <br />1.00 <br />0.1558 <br />0.4896 <br />4.00 <br />0.1670 <br />0.1807 <br />1.00 <br />0.1809 <br />0.6706 <br />5.00 <br />0.1944 <br />0.2094 <br />1.00 <br />0.2094 <br />0.8800 <br />6.00 <br />0.2243 <br />0.2414 <br />1.00 <br />0.2420 <br />1.1220 <br />7.00 <br />0.2585 <br />0.3069 <br />1.00 <br />0.3221 <br />1.4441 <br />8.00 <br />0.3553 <br />0.3923 <br />1.00 <br />0.3941 <br />1.8382 <br />9.00 <br />0.4293 <br />0.4645 <br />1.00 <br />0.4655 <br />2.3037 <br />10.00 <br />0.4996 <br />W <br />N <br />S <br />E <br />ENGINEERS CERTIFICATION <br />I, BRIAN W. COATES, hereby certify that this <br />map has been reviewed by me and is true <br />and correct to the best of my knowledge and <br />information, relying on information supplied <br />by experts employed by Colowyo Coal <br />Company or qualified consultants working <br />for Colowyo Coal Company, and that I am a <br />Professional Engineer licensed in Colorado as <br />required by the provisions of C.R.S. <br />12-25-101 through C.R.S. 12-25-119. IN <br />WITNESS WHEREOF, I have hereunder set <br />my hand and affixed my seal. <br />w C• :Ns <br />55154 <br />-.4/29/20 <br />