Laserfiche WebLink
V <br /> GOLDER <br /> August 5, 2020 Reference No. 20144265-2-L-0 <br /> Ms.Amy Eschberger RECEIVED <br /> t Colorado Division of Reclamation Mining and Safety AUG Department of Natural Resources 10 _67a <br /> ' 1313 Sherman Street, Room 215 UWASION OF RECLAMATION <br /> Denver, Colorado 80203 RAINJNG.cY SAFE <br /> FIRST SEMI-ANNUAL 2020 GROUNDWATER SAMPLING EVENT AT THE BOETTCHER QUARRY <br /> Dear Ms. Eschberger: <br /> On behalf of Holcim (US) Inc., Golder Associates Inc. (Golder) is pleased to submit analytical laboratory results <br /> for the first semi-annual 2020 groundwater sampling event at the Boettcher Limestone Quarry near La Porte, <br /> Colorado. Attached are Tables 1 through 7, summarizing the results, and a copy of the laboratory report <br /> (Attachment 1). Field sheets for the purging and sampling are presented in Attachment 2. In addition to sampling <br /> ' wells MW-1 through MW-7, a field duplicate at MW-5 (MW-20)and a field blank (MW-15)were collected. The <br /> locations of monitoring wells MWA through MW-7 are presented in Figure 1. <br /> In December 2016, the Colorado Division of Reclamation Mining and Safety approved a revision to change the <br /> ' required groundwater monitoring frequency from quarterly to semi-annually (Revision TR07) based on evidence <br /> that the groundwater wells were not fully recharging between sampling events. Figure 2 presents a graph of the <br /> ' monitoring well water elevations measured during each sampling event from 2013 to present. <br /> Upon receipt of the laboratory reports, Golder reviewed the results, and a general analytical data evaluation was <br /> performed. Results of this evaluation included the following: <br /> ' ■ The samples were received by the laboratory at the appropriate temperature. <br /> ■ The required analyses were performed. <br /> ' ■ The analyses were conducted within their respective United States Environmental Protection Agency <br /> (USE PA)-recommended hold times, apart from pH. Measurements for pH should be conducted within <br /> 15 minutes of sample collection; thus, the laboratory pH measurement will always be out of hold time. <br /> Based on the above review, the laboratory results are considered valid for the sampling event. Reported <br /> ' concentrations are consistent with previous events, and the analytes that exceeded the Interim Narrative <br /> Standard for this sampling event are listed by sampling location below: <br /> ■ MW-1: iron, selenium, uranium, sulfate, and gross alpha <br /> ' ■ MW-2: barium, boron, iron, manganese, and chloride <br /> Golder Associates Inc. <br /> 7245 W Alaska Drive,Suite 200,Lakewood,Colorado,USA 80226 T +1 303 980-0540 F +1 303 985-2080 <br /> ' Golder and the G logo are trademarks of Golder Associates Corporation golder.com <br />