My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2020-07-08_REVISION - M1980244 (21)
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1980244
>
2020-07-08_REVISION - M1980244 (21)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2025 2:35:35 AM
Creation date
7/9/2020 8:15:03 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1980244
IBM Index Class Name
Revision
Doc Date
7/8/2020
Doc Name
VOL 2-Phase 2A, Part 3(1 OF 2)
From
CC&V
To
DRMS
Type & Sequence
TR122
Email Name
TC1
MAC
Media Type
D
Archive
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
269
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Newmont-Cripple Creek&Victor Gold Mine ■ <br /> Technical Specification No.02200 REV D <br /> Squaw Gulch VLF ■ <br /> Project No.475.0106.006 <br /> March 13,2020 <br /> 5. Unless otherwise approved by MANAGER and CERTIFYING ENGINEER, the entire fill <br /> surface shall be at or near the same elevation at all times during construction. At all <br /> times during construction, the surface of the fill shall be graded and maintained by <br /> the CONTRACTOR to prevent ponding of water and to allow for storm water <br /> drainage. <br /> 6. Except as otherwise specified or approved by MANAGER and CERTIFYING ENGINEER, <br /> the CONTRACTOR shall dump and spread fill in such a manner so that no excessive <br /> gaps are left between successively dumped loads of materials.The fill shall be leveled <br /> prior to compaction by means of a dozer or grader, or other suitable approved <br /> equipment, to obtain a surface free from depressions. <br /> 7. Except in areas approved by MANAGER and CERTIFYING ENGINEER where space is <br /> limited or otherwise specified, CONTRACTOR shall place fill by routing the hauling <br /> and spreading units approximately parallel to the axis of the fill. As far as practical, <br /> hauling units shall be so routed that they do not follow in the same paths, but split <br /> their tracks evenly across the surface of the fill to enhance compaction. <br /> 8. CONTRACTOR shall apply water required for moisture conditioning on the fill or in <br /> the borrow areas. <br /> CONTRACTOR shall maintain fill materials within the moisture content range <br /> required to permit proper compaction to the specified density with the equipment <br /> being used. The moisture content of the fill materials, prior to and during <br /> compaction, shall be uniform throughout each layer of the material. <br /> Prior to mixing of wet and dry material on the fill to obtain the proper moisture <br /> content, approval shall be obtained from CERTIFYING ENGINEER. Mixed material <br /> shall have a uniform distribution of the moisture content prior to placement on the <br /> subsequent lift. <br /> When materials spread on the fill are too dry for proper compaction, CONTRACTOR <br /> shall spray water on each layer of the fill and shall work the moisture into the fill by <br /> harrowing or other approved means, until a uniform distribution of moisture is <br /> obtained. Material that is too wet for proper compaction, as determined by <br /> CERTIFYING ENGINEER, shall be removed from the fill and/or spread out and <br /> permitted to dry, assisted by disking and harrowing or mixing in dry material when <br /> permitted by CERTIFYING ENGINEER, if necessary, until the moisture content is <br /> reduced to an amount suitable for obtaining the specified degree of compaction, at <br /> no cost to CC&V. <br /> 9. After each layer of fill material has been placed, spread, and moisture-conditioned, <br /> the layer shall be compacted by passing compaction equipment over the entire <br /> surface of the layer a sufficient number of times to obtain the required density, as <br /> specified herein. Compaction shall be accomplished with equipment and by methods <br /> approved by CERTIFYING ENGINEER. If such equipment or methods are found <br /> Page 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.