Laserfiche WebLink
Method/Analysis Information <br /> Product: Solids,Total Dissolved <br /> Analytical Batch: 1269877 Method: EPA 160.1 Solids and Dissolved <br /> Sample Analysis <br /> The following samples were analyzed using the analytical protocol as established in EPA 160.1: <br /> Sample ID Client ID <br /> 316524001 Sunday 1 <br /> 316524002 Sunday 65 <br /> 1202796208 Method Blank(MB) <br /> 1202796209 316547007(CALA-13-24542)Sample Duplicate(DUP) <br /> 1202796210 Laboratory Control Sample(LCS) <br /> The samples in this SDG were analyzed on an"as received"basis. <br /> SOP Reference <br /> Procedure for preparation,analysis and reporting of analytical data are controlled by GEL Laboratories LLC as <br /> Standard Operating Procedure(SOP).The data discussed in this narrative has been analyzed in accordance with <br /> GL-GC-E-001 REV# 13. <br /> Preparation/Analytical Method Verification <br /> The SOP stated above has been prepared based on technical research and testing conducted by GEL Laboratories, <br /> LLC.and with guidance from the regulatory documents listed in this"Method/Analysis Information" section. <br /> Calibration Information <br /> The Solids analysis was performed on a Sartorius Balance BAL216.Solids lab <br /> Initial Calibration <br /> All initial calibration requirements have been met for this SDG. <br /> Quality Control(OC)Information <br /> Method Blank(MB)Statement <br /> The MB analyzed with this SDG met the acceptance criteria. <br /> Laboratory Control Sample(LCS)Recovery <br /> The LCS spike recovery met the acceptance limits. <br /> Page 49 of 86 <br />