Laserfiche WebLink
' Channel Report <br /> Hydraflow Express Extension for Autodesk®AutoCAD®Civil 3D®by Autodesk, Inc. Tuesday,May 19 2020 <br /> ' Morrison Toe Channel Basins G, L - 100 Year <br /> t Triangular Highlighted <br /> Side Slopes (z:1) = 2.00, 2.00 Depth (ft) = 1.06 <br /> Total Depth (ft) = 2.00 Q (cfs) = 10.64 <br /> ' Area (sqft) = 2.25 <br /> Invert Elev (ft) = 6925.00 Velocity (ft/s) = 4.73 <br /> Slope (%) = 10.00 Wetted Perim (ft) = 4.74 <br /> N-Value = 0.060 Crit Depth, Yc (ft) = 1.12 <br /> Top Width (ft) = 4.24 <br /> Calculations EGL (ft) = 1.41 <br /> Compute by: Known Q <br /> Known Q (cfs) = 10.64 <br /> Elev (ft) Section Depth (ft) <br /> 6928.00 3.00 <br /> 6927.50 2.50 <br /> ' 6927.00 2.00 <br /> 6926.50 1.50 <br /> 6926.00 1.00 <br /> 6925.50 0.50 <br /> 6925,00 0.00 <br /> ' 6924.50 -0.50 <br /> 0 1 2 3 4 5 6 7 8 9 10 <br /> ' Reach (ft) <br />