My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2020-01-24_REVISION - M1980244
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1980244
>
2020-01-24_REVISION - M1980244
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2024 4:36:55 PM
Creation date
1/24/2020 3:31:03 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1980244
IBM Index Class Name
Revision
Doc Date
1/24/2020
Doc Name
Request for Technical Revision
From
CC&V
To
DRMA
Type & Sequence
TR120
Email Name
TC1
MAC
AWA
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Cripple Creek&Victor Phone(719)689-2977 <br /> Gold Mining Company Fax(719)689-3254 <br /> PO Box 191 <br /> 100 N 3rd <br /> ANGLOGOLD ASHANTI Victor,CO80860-0191 <br /> ANGLOGOLD ASHANTI (COLORADO) CORP. <br /> week during the injection program. If, during the injection program, the survey data indicates a total vertical <br /> displacement rate of 1-inch per week or greater, then injection activities should be terminated and the injection <br /> pressures revised. <br /> In accordance to the AMEC letter dated 17 December, 2009, the Factor of Safety (FoS) for the Valley Leach <br /> Facility (VLF) will remain at or greater than the minimum acceptable value of 1.5 as long as the injection <br /> guidelines presented in the letter are followed.The injection guidelines are: <br /> 1.The injection wells should be located a minimum of 20 feet from the crest of any ore benches. Only wells that <br /> will have deep (+100 feet) injection depths can be located closer than 20 feet from the bench crest; <br /> 2. Injection pressures in the upper 70 feet should not exceed %:of the overburden pressure. Higher injection <br /> pressures can be used for depths greater than 70 feet, but should not exceed the overburden pressure; and <br /> 3. Injection pressures should always be closely monitored and controlled to avoid any local instabilities. <br /> 3. Electrical Resistivity Characterization and Monitoring <br /> Figures 1 and 2 show the positions of the nine HJ wells along the westernmost edge of the 9925' elevation of <br /> Phase 2. Also shown are the positions of seven additional bore holes distributed over the HJ target area. As part <br /> of CC&V's commitment to monitoring the HJ project and ensuring the safe stable operation of the VLF, these <br /> holes are will be used to install a network of subsurface electrodes that will be used to monitor solution profiles <br /> during injection events using electrical resistivity techniques. <br /> HydroGeophysics Inc. (HGI), a geophysical firm specializing in resistivity monitoring, has been contracted to work <br /> in concert with MRS during the injections. As the saturation of the pore space is increased during the injection, <br /> the electrical resistivity of the heap decreases. Hence, by monitoring the resistivity between various <br /> combinations of electrodes it will be possible for HGI to determine the preferred flow directions at each <br /> injection depth as well the proximity of these flow paths to the surface of the VLF. <br /> HGI has previously demonstrated the benefits of electrical resistivity characterization and monitoring in support <br /> of the HJ process at Newmont, (Rucker, 2009a; Rucker et al., 2009b) establishing very close ties to Metal <br /> Recovery Solutions (MRS) that have continued through the commercialization of HJ. HGI will use the subsurface <br /> electrodes in conjunction with a network of surface electrodes deployed on the surrounding areas to track the <br /> migration of fluid during each injection event. Since the data is gathered in real time, if HGI determines that <br /> solution migration paths are not as desired it will be possible to relay this to MRS operators so that immediate <br /> action can be taken. <br /> As shown in Figures 1 and 2 the network of subsurface electrodes installed in the monitoring bore holes will <br /> surround injection wells labeled HJ-2, HJ-3, and HJ-4. The numeric designation in the well ID denotes the <br /> position of the well in the target area rather than the treatment order - the aforementioned will actually be <br /> treated first. Data generated from injections in these wells will provide an avenue to reconcile physical <br /> operations with analytical relationships and establish a robust baseline to ensure complete process control <br /> during stimulation of subsequent wells. <br />
The URL can be used to link to this page
Your browser does not support the video tag.