Laserfiche WebLink
AUZ Laboratories, Inc. • - - • - • <br /> 2773 Downhill Dnve Steamboat Spnngs, CO 80487 (800)334-5493 - • • <br /> Alexco Water&Environmental Inc. ACZ Project ID: L50149 <br /> METHOD QUAL DESCRIPTION <br /> L50149-01 NG467130 Calcium,dissolved M200.7 ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> WG467252 Chloride SM4500CI-E RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG467461 Cyanide,WAD SM4500-CN I,E-Colohmetric w/ M2 Matrix spike recovery was low,the recovery of the <br /> distillation associated control sample(LCS or LFB)was acceptable. <br /> SM4500-CN I,E-Colonmetric w/ RA Relative Percent Difference(RPD)was not used for data <br /> distillation validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG467130 Manganese,dissolved M200.7 ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> WG467891 Nitrate/Nitnte as N M353 2-H2SO4 preserved RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG467441 Phosphorus,total M365.1-Auto Ascorbic Acid RA Relative Percent Difference(RPD)was not used for data <br /> (digest) validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG467080 Residue,Non-FRerable(TSS)@105C SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG467130 Sodium,dissolved M200.7 ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable <br /> WG467210 Sulfate D516-02/-07-Turbidimetric RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> L50149-02 NG467130 Calcium,dissolved M200 7 ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level The recovery of the associated control sample(LCS <br /> or LFB)was acceptable <br /> WG467252 Chloride SM4500CI-E RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG467461 Cyanide,WAD SM4500-CN I,E-Colorimetric w/ M2 Matrix spike recovery was low,the recovery of the <br /> distillation associated control sample(LCS or LFB)was acceptable <br /> SM4500-CN I,E-Colorimetric w/ RA Relative Percent Difference(RPD)was not used for data <br /> distillation validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG467130 Manganese,dissolved M200 7 ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable <br /> WG467891 Ndrate/Nitrite as N M353 2-H2SO4 preserved RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG467441 Phosphorus,total M365.1-Auto Ascorbic Acid RA Relative Percent Difference(RPD)was not used for data <br /> (digest) validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG467080 Residue,Non-FiRerable(TSS)@105C SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG467130 Sodium,dissolved M200 7 ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> WG467210 Sulfate D516-02/-07-Turbidimetric RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> REPAD.15.06 05.01 <br /> L50149-1909231447 Page 25 of 35 <br />