My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2019-11-27_HYDROLOGY - M1977300 (6)
DRMS
>
Day Forward
>
Hydrology
>
Minerals
>
M1977300
>
2019-11-27_HYDROLOGY - M1977300 (6)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2024 2:53:28 PM
Creation date
12/2/2019 9:31:13 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977300
IBM Index Class Name
Hydrology
Doc Date
11/27/2019
Doc Name Note
Revised Analytics
Doc Name
Water Monitoring - Groundwater and Surface Water
From
Colorado Legacy Land
To
DRMS
Annual Report Year
2019
Report Quarter_Month
Feb
Email Name
AME
MAC
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ADZ Laboratories, Inc. • • • - • - • <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 0 - • • <br /> Alexco Water&Environmental Inc. ACZ Project ID: L50185 <br /> METHODACZ ID WORKNUM PARAMETER QUAL DESCRIPTION <br /> L50185-01 NG467342 Antimony,dissolved M200.8 ICP-MS Q5 Sample received with inadequate chemical preservation. <br /> Additional preservation performed by the laboratory. <br /> Arsenic,dissolved M200 8 ICP-MS Q5 Sample received with inadequate chemical preservation. <br /> Additional preservation performed by the laboratory <br /> WG467461 Cyanide,WAD SM4500-CN I,E-Colonmetric w/ M2 Matrix spike recovery was low,the recovery of the <br /> distillation associated control sample(LCS or LFB)was acceptable. <br /> SM4500-CN I,E-Colormetric w/ RA Relative Percent Difference(RPD)was not used for data <br /> distillation validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG467565 Iron,total M200 7 ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level The recovery of the associated control sample(LCS <br /> or LFB)was acceptable <br /> WG467342 Lead,dissolved M200 8 ICP-MS Q5 Sample received with inadequate chemical preservation <br /> Additional preservation performed by the laboratory. <br /> WG467381 Mercury,dissolved M245 1 CVAA Q5 Sample received with inadequate chemical preservation <br /> Additional preservation performed by the laboratory. <br /> WG467582 Nitrate/Nitrite as N M353 2-H2SO4 preserved RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG467447 Phosphorus,total M365.1-Auto Ascorbic Acid RA Relative Percent Difference(RPD)was not used for data <br /> (digest) validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG467177 Residue,Non-Filterable(TSS)@105C SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG467342 Silver,dissolved M200.8 ICP-MS Q5 Sample received with inadequate chemical preservation. <br /> Additional preservation performed by the laboratory. <br /> Thallium,dissolved M200.8 ICP-MS Q5 Sample received with inadequate chemical preservation. <br /> Additional preservation performed by the laboratory. <br /> WG467403 Uranium,dissolved M200.8 ICP-MS Q5 Sample received with inadequate chemical preservation. <br /> Additional preservation performed by the laboratory. <br /> L60186-02 NG467177 Residue,Non-Filterable(TSS)@105C SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> L50185-03 ✓VG467177 Residue,Non-Filterable(TSS)@105C SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> REPAD.15.06 05.01 <br /> L50185-1909231417 Page 25 of 34 <br />
The URL can be used to link to this page
Your browser does not support the video tag.