Laserfiche WebLink
ADZ Laboratories, Inc. • • • - • - • <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 0 - • • <br /> Alexco Water&Environmental Inc. ACZ Project ID: L50185 <br /> METHODACZ ID WORKNUM PARAMETER QUAL DESCRIPTION <br /> L50185-01 NG467342 Antimony,dissolved M200.8 ICP-MS Q5 Sample received with inadequate chemical preservation. <br /> Additional preservation performed by the laboratory. <br /> Arsenic,dissolved M200 8 ICP-MS Q5 Sample received with inadequate chemical preservation. <br /> Additional preservation performed by the laboratory <br /> WG467461 Cyanide,WAD SM4500-CN I,E-Colonmetric w/ M2 Matrix spike recovery was low,the recovery of the <br /> distillation associated control sample(LCS or LFB)was acceptable. <br /> SM4500-CN I,E-Colormetric w/ RA Relative Percent Difference(RPD)was not used for data <br /> distillation validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG467565 Iron,total M200 7 ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level The recovery of the associated control sample(LCS <br /> or LFB)was acceptable <br /> WG467342 Lead,dissolved M200 8 ICP-MS Q5 Sample received with inadequate chemical preservation <br /> Additional preservation performed by the laboratory. <br /> WG467381 Mercury,dissolved M245 1 CVAA Q5 Sample received with inadequate chemical preservation <br /> Additional preservation performed by the laboratory. <br /> WG467582 Nitrate/Nitrite as N M353 2-H2SO4 preserved RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG467447 Phosphorus,total M365.1-Auto Ascorbic Acid RA Relative Percent Difference(RPD)was not used for data <br /> (digest) validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG467177 Residue,Non-Filterable(TSS)@105C SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG467342 Silver,dissolved M200.8 ICP-MS Q5 Sample received with inadequate chemical preservation. <br /> Additional preservation performed by the laboratory. <br /> Thallium,dissolved M200.8 ICP-MS Q5 Sample received with inadequate chemical preservation. <br /> Additional preservation performed by the laboratory. <br /> WG467403 Uranium,dissolved M200.8 ICP-MS Q5 Sample received with inadequate chemical preservation. <br /> Additional preservation performed by the laboratory. <br /> L60186-02 NG467177 Residue,Non-Filterable(TSS)@105C SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> L50185-03 ✓VG467177 Residue,Non-Filterable(TSS)@105C SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> REPAD.15.06 05.01 <br /> L50185-1909231417 Page 25 of 34 <br />