2019-10-16_HYDROLOGY - M1988112
DRMS
>
Day Forward
>
Hydrology
>
Minerals
>
M1988112
>
2019-10-16_HYDROLOGY - M1988112
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/18/2019 8:49:32 AM
Creation date
10/16/2019 2:15:43 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1988112
IBM Index Class Name
Hydrology
Doc Date
10/16/2019
Doc Name
Water Level Monitoring
From
Battle Mountain
To
DRMS
Annual Report Year
2019
Report Quarter_Month
Sep
Email Name
LJW
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Table 2-Monthly Piezometer Elevations <br /> Monitoring Well Piezometer Depth Depth to Water Depth of Water <br /> Identification Observation Date (ft) (ft) (ft) <br /> P6 09/30/2019 72.46. DRY N/A <br /> P7 09/30/2019 92.50 92.29 0.21 <br /> P8 09/30/2019 97.51 96.70 0.81 <br /> P9 09/30/2019 72.30 71.90 0.40 <br /> P10 09/30/2019 58.30 57.57 0.73 <br /> P11 09/30/2019 41.80 41.39 0.41 <br /> P12 09/30/2019 41.71 41.67 0.04 <br /> P13 09/30/2019 41.34 41.03 0.31 <br /> P14 09/30/2019 41.24 DRY N/A <br /> P15 09/30/2019 41.10 40.87 0.23 <br /> The leak detection system at the TSF Collection Pond was inspected September 30, 2019. A total of 850 <br /> gallons (27.4 GPD) were evacuated from the leak detection system and pumped to the LTF. The LTF <br /> underdrain system flow was measured to be approximately 35.0 gallons per minute(gpm). <br /> West Pit Waste Water Treatment Plant <br /> During the month of September 2019,the West Pit Water Treatment Plant was operated under Colorado <br /> Department of Public Health and Environment(CDPHE)CDPS Permit No.C00045675 for discharge into <br /> the Rito Seco alluvial aquifer. During the month of September, 7,368,800 gallons (22.61 acre-feet) of <br /> treated water was discharged to the Rito Seco and no water was transferred from the West Pit to the LTF. <br /> There was no sludge transferred from the water treatment plant drying pad to the LTF. <br /> BMRI performed the monthly visual seepage expression inspections on September 3022019 in the historic <br /> seepage area identified in Figure 2 of the permit. No seepage expressions were observed in the historic <br /> seepage area during September 2019. <br /> BMRI measured the monthly West Pit backfill, alluvial and monitoring wells as required under in the <br /> QA/QC Plan. Measurements obtained for the monthly wells are shown in Table 3. <br /> Table 3-Monthly and Quarterly Groundwater Depth to Water <br /> Monitoring Well Identification Observation Date Depth to Water <br /> (ft) <br /> BF-4 09/30/2019 24.95 <br /> BF-5R 09/30/2019 30.84 <br /> BF-6 09/30/2019 30.97 <br /> M-6 09/30/2019 DRY <br /> M-7 09/30/2019 DRY <br /> M-8 09/30/2019 DRY <br /> M-9 09/30/2019 141.54 <br /> M-10 09/30/2019 25.55 <br /> M-11R 09/30/2019 38.84 <br /> M-12 09/30/2019 174.84 <br /> M-13R 09/30/2019 125.86 <br /> M-14 09/30/2019 130.92 <br /> M-15 09/30/2019 92.97 <br /> M-16 09/30/2019 22.84 <br /> M-17 09/30/2019 30.52 <br /> M-18 09/30/2019 26.74 <br /> M-19 09/30/2019 23.96 <br />