Laserfiche WebLink
A UZ Laboratories, Inc. • • • • - • <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 0 - • <br /> ICItasca Denver, Inc. ACZ Project ID: L43419 <br /> METHODACZ ID WORKNUM PARAMETER QUAL DESCRIPTION <br /> L43419-01 WG445354 Aluminum(MWMT) M6010B ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG444963 Aluminum,total(3050) M6010B ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> WG445550 Antimony(MWMT) M6020 ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG444996 Antimony,total(3050) M6020 ICP-MS M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> WG445550 Arsenic(MWMT) M6020 ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG445354 Barium(MWMT) M6010B ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG444963 Barium,total(3050) M6010B ICP ZH Serial Dilution exceeded the acceptance criteria. Matrix <br /> interference[physical or chemical]is suspected. <br /> WG445550 Beryllium(MWMT) M6020 ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG445354 Boron(MWMT) M6010B ICP B1 Target analyte detected in prep/method blank at or above <br /> the method reporting limit.See Case Narrative. <br /> M6010B ICP ZG The ICP or ICP-MS Serial Dilution was not used for data <br /> validation because the sample concentration was less than <br /> 50 times the MDL. <br /> Calcium(MWMT) M6010B ICP B1 Target analyte detected in prep/method blank at or above <br /> the method reporting limit.See Case Narrative. <br /> M6010B ICP RD For a solid matrix,the duplicate RPD(spike or matrix) <br /> exceeded the control limit,which is attributable to the non- <br /> homogeneity of the sample. <br /> WG445498 Chloride(MWMT) SM4500CI-E HD Analysis is outside the intended scope of the method, <br /> which does not provide hold time information for soil <br /> extracts. No hold time is observed for collection to <br /> extraction. The referenced method hold time is observed <br /> for extraction-to-analysis. <br /> SM4500CI-E RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG445354 Chromium(MWMT) M6010B ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG445552 Cyanide,WAD(MWMT) SM4500-CN I,E-Colorimetric w/ M1 Matrix spike recovery was high,the recovery of the <br /> distillation associated control sample(LCS or LFB)was acceptable. <br /> SM4500-CN I,E-Colorimetric w/ RA Relative Percent Difference(RPD)was not used for data <br /> distillation validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG445704 Fluoride(MWMT) SM450OF-C 61 Target analyte detected in prep/method blank at or above <br /> the method reporting limit.See Case Narrative. <br /> SM450OF-C RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG445354 Iron(MWMT) M6010B ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<lox MDL). <br /> WG444963 Iron,total(3050) M6010B ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> M6010B ICP ZH Serial Dilution exceeded the acceptance criteria. Matrix <br /> interference[physical or chemical]is suspected. <br /> WG445550 Lead(MWMT) M6020 ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG445354 Lithium(MWMT) M6010B ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> REPAD.15.06.05.01 <br /> L4341 9-1 805031 41 8 Page 24 of 47 <br />