Laserfiche WebLink
ADZ Laboratories, Inc. • • • ' • <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 - • • <br /> HCitasca Denver, Inc. ACZ Project ID: L43424 <br /> PARAMETER METHOD QUAL DESCRIPTION <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG445354 Lithium(MWMT) M6010B ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG444963 Lithium,total(3050) M6010B ICP ZG The ICP or ICP-MS Serial Dilution was not used for data <br /> validation because the sample concentration was less than <br /> 50 times the MDL. <br /> M6010B ICP ZQ Analyte was not evaluated in the laboratory control <br /> standard. Either the analyte is not included in the scope of <br /> the analytical method or a commercial standard containing <br /> the analyte is not available. <br /> Manganese,total(3050) M6010B ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> M6010B ICP ZH Serial Dilution exceeded the acceptance criteria. Matrix <br /> interference[physical or chemical]is suspected. <br /> WG445100 Mercury(MWMT) M7470 CVAA H3 Sample was received and analyzed past holding time. <br /> M7470 CVAA RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG444901 Mercury by Direct Combustion AA M7473 CVAAS H3 Sample was received and analyzed past holding time. <br /> M7473 CVAAS RD For a solid matrix,the duplicate RPD(spike or matrix) <br /> exceeded the control limit,which is attributable to the non- <br /> homogeneity of the sample. <br /> WG445354 Molybdenum(MWMT) M6010B ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG444963 Molybdenum,total(3050) M6010B ICP M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> M6010B ICP ZG The ICP or ICP-MS Serial Dilution was not used for data <br /> validation because the sample concentration was less than <br /> 50 times the MDL. <br /> WG444619 NAG Sequential NAG-EGI 2002 N1 See Case Narrative. <br /> WG444963 Nickel,total(3050) M6010B ICP ZG The ICP or ICP-MS Serial Dilution was not used for data <br /> validation because the sample concentration was less than <br /> 50 times the MDL. <br /> WG445105 Nitrate/Nitrite as N(MWMT) M353.2-Automated Cadmium HD Analysis is outside the intended scope of the method, <br /> Reduction which does not provide hold time information for soil <br /> extracts. No hold time is observed for collection to <br /> extraction. The referenced method hold time is observed <br /> for extraction-to-analysis. <br /> M353.2-Automated Cadmium RA Relative Percent Difference(RPD)was not used for data <br /> Reduction validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG445834 Nitrogen,total Kjeldahl(MWMT) M351.2-Block Digestor HD Analysis is outside the intended scope of the method, <br /> which does not provide hold time information for soil <br /> extracts. No hold time is observed for collection to <br /> extraction. The referenced method hold time is observed <br /> for extraction-to-analysis. <br /> M351.2-Block Digestor RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG444619 pH After Oxidation Sequential NAG-EGI 2002 N1 See Case Narrative. <br /> WG445354 Potassium(MWMT) M6010B ICP RD For a solid matrix,the duplicate RPD(spike or matrix) <br /> exceeded the control limit,which is attributable to the non- <br /> homogeneity of the sample. <br /> WG445300 Residue,Filterable(TDS)@180C SM2540C B7 Target analyte detected in prep/method blank at or above <br /> (MWMT) acceptance limit. Sample value is>10X the concentration <br /> in the method blank. <br /> SM2540C RD For a solid matrix,the duplicate RPD(spike or matrix) <br /> exceeded the control limit,which is attributable to the non- <br /> homogeneity of the sample. <br /> WG445173 Selenium,total(3050) M6020 ICP-MS ZG The ICP or ICP-MS Serial Dilution was not used for data <br /> validation because the sample concentration was less than <br /> 50 times the MDL. <br /> REPAD.15.06.05.01 <br /> L43424-1805031420 Page 25 of 47 <br />