My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2019-10-01_HYDROLOGY - M1977300 (2)
DRMS
>
Day Forward
>
Hydrology
>
Minerals
>
M1977300
>
2019-10-01_HYDROLOGY - M1977300 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/6/2025 4:45:25 AM
Creation date
10/2/2019 1:21:34 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977300
IBM Index Class Name
HYDROLOGY
Doc Date
10/1/2019
Doc Name
Water Level Monitoring
From
Colorado Legacy Land
To
DRMS
Email Name
MAC
AME
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
164
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ACZ Laboratories, Inc. <br /> 2773 Downhill Dnve Steamboat Springs,CO 80487 (800)334-5493 <br /> 'Report Header Explanations <br /> Batch A distinct set of samples analyzed at a speck time <br /> Found Value of the QC Type of interest <br /> Limit Upper limit for RPD,in% <br /> Lower Lower Recovery Limit,in% (except for LCSS,mg/Kg) <br /> MDL Method Detection Limit. Same as Minimum Reporting Limit unless omitted or equal to the PQL(see comment#5). <br /> Allows for instrument and annual fluctuations <br /> PCN/SCN A number assigned to reagents/standards to trace to the manufacturer's certificate of analysis <br /> PQL Practical Quantrtation Limit. Synonymous with the EPA term"minimum level". <br /> QC True Value of the Control Sample or the amount added to the Spike <br /> Rec Recovered amount of the true value or spike added,in%(except for LCSS,mg/Kg) <br /> RPD Relative Percent Difference,calculation used for Duplicate QC Types <br /> Upper Upper Recovery Limit,in% (except for LCSS,mg/Kg) <br /> Sample Value of the Sample of interest <br /> QC Sample Types <br /> AS Analytical Spike(Post Digestion) LCSWD Laboratory Control Sample-Water Duplicate <br /> ASD Analytical Spike(Post Digestion)Duplicate LFB Laboratory Fortified Blank <br /> CCB Continuing Calibration Blank LFM Laboratory Fortified Matrix <br /> CCV Continuing Calibration Verification standard LFMD Laboratory Fortified Matrix Duplicate <br /> DUP Sample Duplicate LRB Laboratory Reagent Blank <br /> ICB Initial Calibration Blank MS Matrix Spike <br /> /CV Initial Calibration Verification standard MSD Matrix Spike Duplicate <br /> ICSAB Inter-element Correction Standard-A plus B solutions PBS Prep Blank-Soil <br /> LCSS Laboratory Control Sample-Soil PBW Prep Blank-Water <br /> LCSSD Laboratory Control Sample-Soil Duplicate PQV Practical Quantitation Verification standard <br /> LCSW Laboratory Control Sample-Water SDL Serial Dilution <br /> QC Sample Type Explanations <br /> Blanks Verifies that there is no or minimal contamination in the prep method or calibration procedure. <br /> Control Samples Verifies the accuracy of the method,including the prep procedure <br /> Duplicates Verifies the precision of the instrument and/or method <br /> Spikes/Fortfied Matrix Determines sample matrix interferences,if any <br /> Standard Verfies the validity ofthe calibration. <br /> R R <br /> B Analyte concentration detected at a value between MDL and PQL The associated value is an estimated quantity <br /> H Analysis exceeded method hold time pH is a field test with an immediate hold time. <br /> L Target analyte response was below the laboratory defined negative threshold. <br /> U The material was analyzed for,but was not detected above the level of the associated value. <br /> The associated value is either the sample quantitatron limit or the sample detection limit <br /> (1) EPA 600/4-83-020. Methods for Chemical Analysis of Water and Wastes,March 1983. <br /> (2) EPA 600/R-93-100 Methods for the Determination of Inorganic Substances in Environmental Samples,August 1993. <br /> (3) EPA 600/R-94-111. Methods for the Determination of Metals in Environmental Samples-Supplement I,May 1994 <br /> (4) EPA SW-846. Test Methods for Evaluating Solid Waste. <br /> (5) Standard Methods for the Examination of Water and Wastewater <br /> (1) QC results calculated from raw data Results may vary slightly rf the rounded values are used in the calculations. <br /> (2) Soil,Sludge,and Plant matrices for Inorganic analyses are reported on a dry weight basis. <br /> (3) Animal matrices for Inorganic analyses are reported on an"as received"basis <br /> (4) An asterisk in the"XQ"column indicates there is an extended qualifier and/or certification qualifier <br /> associated with the result <br /> (5) If the MDL equals the PQL or the MDL column is omitted,the PQL is the reporting limit <br /> For a complete list of ACZis Extended Qualifiers,please click <br /> haps//ac7 corn/N%p-content/upload,/_'1119 04 1 \t-t)ual-List pdf <br /> REP001 03 15 02 <br /> L52170-1909231414 Page 7 of 35 <br />