My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2019-08-21_HYDROLOGY - M1977300
DRMS
>
Day Forward
>
Hydrology
>
Minerals
>
M1977300
>
2019-08-21_HYDROLOGY - M1977300
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2024 12:18:33 PM
Creation date
8/22/2019 12:00:26 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977300
IBM Index Class Name
HYDROLOGY
Doc Date
8/21/2019
Doc Name
Water Level Monitoring
From
Colorado Legacy Land
To
DRMS
Annual Report Year
2019
Report Quarter_Month
Jul
Email Name
MAC
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ACZ Laboratories, Inc. • • • <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 - • • <br /> Alexco Water& Environmental Inc. ACZ Project ID: L53488 <br /> METHODACZ ID WORKNUM PARAMETER <br /> L53488-01 NG478037 Cyanide,WAD SM4500-CN I,E-Colorimetric wl 06 Sample was received above recommended temperature. <br /> distillation <br /> SM4500-CN I,E-Colorimetric w/ RA Relative Percent Difference(RPD)was not used for data <br /> distillation validation because the.concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG479202 Fluoride SM450OF-C Q6 Sample was received above recommended temperature. <br /> WG479075 Nitrate/Nitrite as N M353.2-H2SO4 preserved Q6 Sample was received above recommended temperature. <br /> M353.2-H2SO4 preserved RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG478702 Phosphorus,total M365.1-Auto Ascorbic Acid Q6 Sample was received above recommended temperature. <br /> (digest) <br /> M365.1-Auto Ascorbic Acid RA Relative Percent Difference(RPD)was not used for data <br /> (digest) validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG478042 Residue,Filterable(TDS)@180C SM2540C Q6 Sample was received above recommended temperature. <br /> SM2540C RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG477993 Residue,Non-Filterable(TSS)@105C SM2540D Q6 Sample was received above recommended temperature. <br /> SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> SM2540D Z3 Sample volume yielded a residue less than 2.5 mg <br /> WG479255 Total Hot Plate Digestion M200.2 ICP-MS DJ Sample dilution required due to insufficient sample. <br /> L53488-02 NG478037 Cyanide,WAD SM4500-CN I,E-Colorimetric w/ Q6 Sample was received above recommended temperature. <br /> distillation <br /> SM4500-CN I,E-Colorimetric wl RA Relative Percent Difference(RPD)was not used for data <br /> distillation validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1Ox MDL). <br /> WG479202 Fluoride SM450OF-C Q6 Sample was received above recommended temperature. <br /> WG479075 Nitrate/Nitrite as N M353.2-H2SO4 preserved Q6 Sample was received above recommended temperature. <br /> M353.2-H2SO4 preserved RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MIX). <br /> W G478702 Phosphorus,total M365.1-Auto Ascorbic Acid Q6 Sample was received above recommended temperature. <br /> (digest) <br /> M365.1-Auto Ascorbic Acid RA Relative Percent Difference(RPD)was not used for data <br /> (digest) validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG478042 Residue,Filterable(TDS)@180C SM2540C 06 Sample was received above recommended temperature. <br /> SM2540C RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG477993 Residue,Non-Filterable(TSS)@105C SM2540D Q6 Sample was received above recommended temperature. <br /> SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> SM2540D Z3 Sample volume yielded a residue less than 2.5 mg <br /> WG479255 Total Hot Plate Digestion M200.2 ICP-MS DJ Sample dilution required due to insufficient sample. <br /> REPAID.15.06.05.01 <br /> L53488-1908160933 Page 11 of 21 <br />