Laserfiche WebLink
January 9, 1996 -2- 943-2847.001 <br /> 2. LQW Volume Solution Collection Fill <br /> U. S. Standard Percent Passing <br /> Sieve Size by DU Weight <br /> 1 inch 100 <br /> 3/8 inch 40 - 70 <br /> No. 4 5 - 55 <br /> No. 200 0 - 10 <br /> 3. Ironclad Soil Liner Fill <br /> U. S. Standard Percent Passing <br /> Sieve Size by Dry Weight <br /> 2 inch 100 <br /> 3/4 inch. 90 - 100 <br /> 3/8 inch 70 - 100 <br /> No. 4 50 - 100 <br /> No. 40 '70 - 50 <br /> No. 200 15 - 50 <br /> 4. Area No. 2 Soil Liner Fiji <br /> U. S. Standard Percent Passing <br /> Sieve Size by Dry Weight <br /> 2 inch .100 <br /> 3/4 inch 75 - 100 <br /> 3/8 inch 70 - 100 <br /> No. 4 60 - 1C►O <br /> No. 40 50 - 80 <br /> No. 200 35 - 60 <br /> Testing Procedure <br /> The interface shear strength testing was performed in general accordance with the <br /> American Society for Testing and Materials (ASTM) Standard Test Method D5321, <br /> "Determining the Coefficient of Soil and Geosynthetic or Geosynthetic and Geosyntheric <br /> Friction by the Direct Shear Method". Tests were conducted at normal stresses ranging <br /> from 50 psi to 150 psi in a direct shear device containing an upper and lower shear box. <br /> The upper shear box measures 12 inches by 12 inches in plan and 3 inches in depth. The <br /> lower shear box measures 12 inches by 14 inches in plan and 3 inches in depth. Tests <br /> conducted at a normal stress of 300 psi used a smaller upper shear box:, which measured 6 <br /> inches by 6 inches in plan and 3 inches in depth. <br /> Golder Associates <br />