My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2019-07-02_REVISION - M1977342
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1977342
>
2019-07-02_REVISION - M1977342
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2024 3:54:46 AM
Creation date
7/8/2019 1:31:11 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977342
IBM Index Class Name
REVISION
Doc Date
7/2/2019
Doc Name
Request for Technical Revision
From
Climax Molybdenum
To
DRMS
Type & Sequence
TR31
Email Name
PSH
MAC
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-Vail YMV515"IlI <br /> TR31 <br /> PSH1mac <br /> Climax Molybdenum COLORADO OPERATIONS <br /> Henderson Mine and Mill <br /> ® P.O. Box 68 <br /> A Freeport-McMoRan Company Empire, CO 80438 <br /> Phone (303) 569-3221 <br /> Fax(303) 569-2830 <br /> July 1, 2019 <br /> Sent Via Email and UPS Certified Mail: 1Z804641NW98276206 R196111vLaV <br /> 5$ V <br /> Mr. Peter Hays JUL 0 2 2m o A <br /> Environmental Protection Specialist ^' <br /> 1313 Sherman Street, Room 215 DNI"OF RECLAMATION <br /> Denver, CO 80203 NNINGMND SMFETY <br /> Re: Climax Molybdenum Company, Henderson Mill, Permit No. M-1977-342 <br /> Proposed Technical Revision No. 31,Additional 3 Dam Seepwater Return Line Clean-out Ports <br /> Dear Mr. Hays, <br /> Climax Molybdenum Company (CMC) is hereby submitting this request for a new Technical Revision (TR-31) for <br /> the addition of clean-out ports to the 3 Dam Seepwater Return Pipelines. The 3 Dam Seepwater Pipelines consist <br /> of two 10-inch HDPE lines, one primary and one backup. The lines travel from the 3 Dam Seepwater Collection <br /> Vault, at the toe of 3 Dam, to the 3 Dam Seepwater Outfall Vault, adjacent to the Ute Park Pump station. The d <br /> lines convey seepwater from the toe of 3 dam to the Ute Park Pump Station, which ultimately conveys the water d IC' <br /> back into the tailing storage facility. Further information on the seepwater return lines can be found in the <br /> Technical Revision 09 documentation. <br /> Currently there are four existing clean-out ports installed in each line, which Henderson has determined to be <br /> insufficient to allow adequate cleaning of the lines. Henderson is proposing to add three additional clean-outs to <br /> each line. The alignment of the pipelines, existing clean-out ports, and proposed clean-out port locations are <br /> included in the attached drawings (attachment 1). <br /> Each additional clean-out will consist of a 10-inch diameter Standard Dimension Ratio (SDR) 17 HDPE pipeline <br /> that will be plumbed into the 3 Dam Seepwater Return lines via a 10-inch molded tee. The clean-out ports will rise <br /> 3 feet above ground level and will be closed with a 10-inch removable blind flange. 5-foot bollards will be installed <br /> adjacent to the clean-out ports as protection. Drawings detailing the clean-out port design can also be found in <br /> attachment 1. Construction is planned to be completed summer of 2019. <br /> A check in the amount of$1,006.00 is included with this submittal to cover fees for this Technical Revision. If you <br /> have any comments, questions, or concerns regarding this project, please contact me at 720-942-3480 or Miguel <br /> Hamarat at 720-942-3255. <br /> Sincerely, <br /> Amber Parmet <br /> Senior Environmental Engineer <br /> Climax Molybdenum Company <br /> Henderson Operations <br />
The URL can be used to link to this page
Your browser does not support the video tag.