Laserfiche WebLink
ADZ Laboratories, Inc. • • • - • <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 - • • <br /> eardon Steel LLC ACZ Project ID: L49791 <br /> METHODACZ ID WORKNUM PARAMETER QUAL DESCRIPTION <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1Ox MDL) <br /> WG466717 Iron,total(3050) M6010D ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level The recovery of the associated control sample(LCS <br /> or LFB)was acceptable <br /> WG466578 Lead(1312) M6020B ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG466896 Lead,total(3050) M6020B ICP-MS MA Recovery for either the spike or spike duplicate was outside <br /> of the acceptance limits,the RPD was within the <br /> acceptance limits <br /> M6020B ICP-MS ZH Serial Dilution exceeded the acceptance criteria Matrix <br /> interference[physical or chemical]is suspected <br /> WG466546 Magnesium(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> Manganese(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG466753 Manganese,total(3050) M6010D ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level The recovery of the associated control sample(LCS <br /> or LFB)was acceptable <br /> WG466902 Mercury(1312) M7470A CVAA RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG466716 Neutralization Potential as CaCO3 M600/2-78-054 3 2 3 RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG466546 Nickel(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> Potassium(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG466578 Selenium(1312) M6020B ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG466546 Silver(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> Sodium(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG466388 Sulfate(1312 DI) D516-07-Turbidimetric HD Analysis is outside the intended scope of the method,which <br /> does not provide hold time information for soil extracts No <br /> hold time is observed for collection to extraction The <br /> referenced method hold time is observed for extraction-to- <br /> analysis <br /> D516-07-Turbidimetric M1 Matrix spike recovery was high,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable <br /> D516-07-Turbidimetric RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG466649 Sulfur Pyritic Sulfide M600/2-78-054 3 2 4 RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> Sulfur Sulfate M600/2-78-054 3 2 4 RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG466578 Thallium(1312) M6020B ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG466896 Thallium,total(3050) M6020B ICP-MS D1 Sample required dilution due to matrix <br /> WG466708 Total Alkalinity SM2320B-Titration RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> REPAD.15.06.05.01 <br /> L49791-1902271021 Page 22 of 27 <br />