My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2019-05-29_PERMIT FILE - M2019031 (7)
DRMS
>
Day Forward
>
Permit File
>
Minerals
>
M2019031
>
2019-05-29_PERMIT FILE - M2019031 (7)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/5/2025 6:43:04 AM
Creation date
5/30/2019 1:45:47 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M2019031
IBM Index Class Name
Permit File
Doc Date
5/29/2019
Doc Name
Application
From
Atlas Mining and Reclamation LLC
To
DRMS
Email Name
THM
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ADZ Laboratories, Inc. • - • - • <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 - • • <br /> .eardon Steel LLC ACZ Project ID: L49574 <br /> METHODACZ ID WORKNUM PARAMETER QUAL DESCRIPTION <br /> L49574-01 NG465804 Aluminum(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG465707 Aluminum,total(3050) M6010D ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level The recovery of the associated control sample(LCS <br /> or LFB)was acceptable <br /> WG465763 Antimony(1312) M6020B ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG465683 Antimony,total(3050) M6020B ICP-MS M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable <br /> WG465763 Arsenic(1312) M6020B ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG465804 Barium(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG465707 Barium,total(3050) M6010D ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level The recovery of the associated control sample(LCS <br /> or LFB)was acceptable <br /> WG465804 Beryllium(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG465621 Bicarbonate as CaCO3 SM2320B-Titration Q6 Sample was received above recommended temperature <br /> WG465804 Cadmium(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> Calcium(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG465621 Carbonate as CaCO3 SM2320B-Titration Q6 Sample was received above recommended temperature <br /> WG465689 Chloride(1312 DI) SM4500CI-E HD Analysis is outside the intended scope of the method,which <br /> does not provide hold time information for soil extracts No <br /> hold time is observed for collection to extraction The <br /> referenced method hold time is observed for extraction-to- <br /> analysis <br /> SM4500CI-E RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG465804 Chromium(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> Cobalt(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG465621 Conductivity @25C(1312-DI) SM2510B Q6 Sample was received above recommended temperature <br /> SM2510B RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG465804 Copper(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG465621 Hydroxide as CaCC3 SM2320B-Titration Q6 Sample was received above recommended temperature <br /> WG465804 Iron(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG465707 Iron,total(3050) M6010D ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level The recovery of the associated control sample(LCS <br /> or LFB)was acceptable <br /> WG465763 Lead(1312) M6020B ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> M6020B ICP-MS ZG The ICP or ICP-MS Serial Dilution was not used for data <br /> validation because the sample concentration was less than <br /> REPAD 15 06 05 01 <br /> L49574-1902071612 Page 22 of 28 <br />
The URL can be used to link to this page
Your browser does not support the video tag.