Laserfiche WebLink
Ouray Silver Mines Inc.Technical Revision 09TablesTable 6. Groundwater Parameter List with StandardsParameter GW standard Method MDL UnitPhosphorus, ortho dissolved report M365.1 - Automated Ascorbic Acid 0.02 mg/LPotassium, dissolved report M200.7 ICP 0.2 mg/LResidue, Filterable (TDS) @180C 400 SM2540C 10 mg/LResidue, Non-Filterable (TSS) @105C report SM2540C 5 mg/LSelenium, dissolved 0.005 M200.8 ICP-MS 0.0001 mg/LSilica, dissolved report M200.7 ICP 0.2 mg/LSilver, dissolved 0.0001 M200.8 ICP-MS 0.00005 mg/LSodium, dissolved report M200.7 ICP 0.2 mg/LSulfate 250 C516-02/-07 - Turbidimetric 5 mg/LSum of Anions report Calculation meq/LSum of Cations report Calculation meq/LTDS (calculated) none Calculation mg/LTDS (ratio - measured/calculated) none CalculationThallium, dissolved report M200.8 ICP-MS 0.0001 mg/LTotal Alkalinity report SM2320B - Titration 2 mg/LUranium, dissolved report M200.8 ICP-MS 0.0001 mg/LVanadium, dissolved 0.1 M200.7 ICP 0.005 mg/LZinc, dissolved 0.713 M200.7 ICP 0.01 mg/L