Laserfiche WebLink
E 11170 P*,PV,-CO-R V. I i 'C <br /> GCC Pueblo David Bemis <br /> 3372 Lime Road Project Number. [none] <br /> Pueblo CO 81004 Project: Groundwater Monitoring <br /> MW-6 <br /> 1211212018 1:30:OOPM <br /> Min Detection Reporting <br /> Analyte Result Limit Limit Units Dilution Batch Prepared Analyzed Notes <br /> Accutest Laboratories <br /> Y812185-02(Water) <br /> Anions by 300.0 <br /> Fluoride ND 1.0 m9& 10 11111 12/12/2018 12113/2018 <br /> Nitrogen,Nitrite ND 0.040 <br /> Dissolved Metals by 6010C <br /> Aluminum ND 68.0 200 uglL 1 1832271 12/16/2018 12J17/2018 u <br /> Arsenic ND 5.00 30.0 u <br /> Beryllium ND 1.00 5.00 u <br /> Boron 624 15.0 50.0 • ' <br /> Cadmium ND 1.00 5.00 • • u <br /> Chromium ND 1.00 5.00 • u <br /> Cobalt 6.01 1.00 5.00 <br /> Copper ND 3.00 10.0 • u <br /> Iron ND 30.0 100 • u <br /> Lead 3.99 3.30 10.0 • J <br /> Manganese 663 2.00 10.0 <br /> Nickel 17.1 1.50 5.00 " • ' <br /> Selenium 6.19 6.00 30.0 • a <br /> Vanadium 1.16 1.00 5.00 d <br /> Zinc 8.99 3.30 10.0 a <br /> Dissolved Metals by 6020A <br /> Origins Laboratory,Inc. <br /> The results in this report apply to the samples analyzed in <br /> accordance with the chain of custody document.This <br /> analytical report must be reproduced in Its entirety. <br /> U Page 7 of 17 <br /> Jen Pepegrini,Project Manager <br />