Laserfiche WebLink
Table 1.Proposed Quarterly Sampling Suite <br /> Surface Water Quality Standard, <br /> t 17b, Domestic Water <br /> Segment Included in Current Ralston Creek 17b 2018 Included in Current Supply-Drinking <br /> Surface Water Groundwater Sample Water Standards <br /> Anal to Units Sample Suites ? Acute Chronic Suite? CDPHE 2016 <br /> Metals Total <br /> Aluminum µg/L Yes,Table 1 Yes,Table 2 <br /> Antimony µg/L Yes,Table 1 none none Yes,Table 2 <br /> Arsenic µg/L Yes,Table 1 and 0.02 - Yes,Table 2 <br /> Code 3 <br /> Boron µg/L Yes,Table 1 - 750 Yes,Table 5 <br /> Chromium III= Yes,Table 5(Mine <br /> Chromium µg/L Yes,Table 1 50 - Pool Only,Sample ID= <br /> RAW FEED <br /> Copper µg/L Yes,Table 1 21.3 13.6 Yes,Table 2 1,000 <br /> Iron µg/L Yes,Table 1 - 1,000 Yes,Table 2 300 <br /> Lead µg/L Yes,Table 1 50 Yes,Table 2 50 <br /> Manganese µg/L Yes,Table 1 3,513.36 1,941.14 Yes,Table 2 50 <br /> Mercury µg/L Yes,Table 1 - 0.01 Yes,Table 2 Non-Detect <br /> Molybdenum µg/L Yes,Table 1 none 150 No 210 <br /> Silver µg/L Yes,Table 1 4.7 0.17 Yes,Table 2 50 <br /> Thallium L Yes,Table 1 none none Yes,Table 2 2 <br /> Uranium µg/L Yes,Code 1 and 4,115.95 2,570.93 No 30 <br /> Code 3 USEPA MCL=30 USEPA MCL=30 <br /> Zinc µg/L Yes,Table 1 249.51 188.98 1 Yes,Table 2 5,000 <br /> Aluminum µg/L Yes,Table 1 Yes,Table 2 5,000 <br /> Antimony µg/L Yes,Table 1 none none Yes,Table 2 6 <br /> Yes,Table 5(Mine <br /> Arsenic µg/L Yes,Code 3 0.02 --- Pool Only,Sample ID= 100 <br /> RAW FEED <br /> Boron mg/L Yes,Table 1 --- 0.75 No 750 <br /> Chromium mg/L No Chromium VI j Chromium III=110.58 No 100 <br /> 16 Chromium VI=11 <br /> PAGE 6 OF 24 <br />