Laserfiche WebLink
Subsidence Evaluation for the <br />Exhibit 60E Southern Panels, Apache Rocks West, & Sunset Trail Mining Areas Page 18 <br />and from 0.007 to 0.026 (0.7 to 2.6 percent) where the extraction thickness equals 14 <br />feet. <br />Horizontal compressive strain ranges from -0.004 to -0.018 (-0.4 to -1.8 percent) where <br />the extraction thickness equals 9 feet, and -0.007 to -0.028 (-0.7 to -2.8 percent) where <br />it equals 14 feet (Table 2). <br />The E -seam panels El to E5 and B -seam panels B26 to B29 occur on top of one another, but are <br />not stacked based on the current panel layout. However, to be conservative, the strain of the two <br />seams is assumed to be additive. <br />• For E -seam and B -seam panels, projected horizontal tensile strain ranges from 0.009 <br />to 0.042 (0.9 to 4.2 percent) where the planned coal extraction thickness is 9 feet, and <br />from 0.014 to 0.065 (1.4 to 6.5 percent) where the extraction thickness equals 14 feet. <br />Horizontal compressive strain ranges from -0.009 to -0.045 (-0.9 to -4.5 percent) where <br />the extraction thickness equals 9 feet, and -0.014 to -0.070 (4.4 to -7.0 percent) where <br />it equals 14 feet (Table 2). <br />Apache Rocks West Mining <br />Maximum tensile and compressive horizontal strains are calculated, using the values obtained from <br />the area of the West Elk Mine, and as projected in Figure 5 (Table 3). These values are believed <br />to be conservative, based on Dunrud's annual observations in the Apache Rocks West mining area. <br />Panels E10 to E12: For these panels, projected horizontal tensile strain ranges from <br />0.007 to 0.028 (0.7 to 2.8 percent) where the planned coal extraction thickness is 10 <br />feet, and from 0.009 to 0.039 (0.9 to 3.9 percent) where the extraction thickness equals <br />14 feet. <br />Horizontal compressive strain ranges from -0.007 to -0.030 (47 to -3.0 percent) where <br />the extraction thickness equals 10 feet, and -0.009 to -0.042 (-0.9 to -4.2 percent) where <br />it equals 14 feet (Table 3). <br />Panels B12 to B13 A: For these panels, projected horizontal tensile strain ranges from <br />0.007 to 0.018 (0.7 to 1.8 percent) where the planned coal extraction thickness is 12 <br />feet. <br />Horizontal compressive strain ranges from -0.007 to -0.019 (-0.7 to -1.9 percent) where <br />the extraction thickness equals 12 feet. <br />The E -seam panels E10 to E12 and B -seam panels B12 to 13A occur on top of one another, but <br />are not stacked based on the current panel layout. However, to be conservative, the strain of the <br />two seams is assumed to be additive. <br />• For E -seam and B -seam panels, projected horizontal tensile strain ranges from 0.013 <br />to 0.046 (1.3 to 4.6 percent) where the planned coal extraction thickness is 10 feet, and <br />from 0.016 to 0.057 (1.6 to 5.7 percent) where the extraction thickness equals 14 feet. <br />831-032.816 Wright Water Engineers, Inc. <br />October 2018 <br />