Table 1.Proposed Qu rterly Sampling Suite
<br /> Included in Included in Current Water Quality Standard,Segment 17b,
<br /> Units Current Surface Water Ralston Creek(CDPHE 2018)
<br /> Groundwater
<br /> Sample Suite? Sample Suite(s)?
<br /> Analyte Acute Chronic Recommendation
<br /> Boron m L Yes,Table 2 No --- 0.75 Remove. Analyte is ND in 100%of surface water samples analytes in EPP Whetstone,2016).
<br /> Chromium III= Remove. Analyte is ND in 100%of surface water samples analytes in EPP(Whetstone,2016)and analyte is reported monthly for surface
<br /> Chromium mg/L Yes,Table 2 Chromium VI=16 110.58
<br /> No Chromium VI=11 water under the NOV/CDO(CDPHE,2011)Sample Suite.
<br /> Copper µg/L Yes,Table 2 Yes,Table 1 21.3 13.6 Remove.Analyte is reported monthly for surface water under the NOV/CDO(CDPHE,2011)Sample Suite.
<br /> Cyanide(weak acid dissociable) µg/L No. Yes,Table 1 5 --- Remove. Analyte is ND in 100%of surface water samples analytes in EPP(Whetstone,2016)and analyte is reported monthly for surface
<br /> water under the NOV/CDO(CDPHE,2011)Sample Suite.
<br /> Iron µg/L Yes,Table 2 Yes,Table 1 --- 300 Retain for quarterly analysis.
<br /> Lead m L Yes,Table 2 No 109.46 4.27 Remove. Analyte is ND in 100%of surface water samples analytes in EPP Whetstone,2016).
<br /> Manganese µ L Yes,Table 2 Yes,Table 1 3,513.36 1,941.14 Retain for quarterly analysis.
<br /> Mercury m L Yes,Table 2 No - 0.01 Retain for quarterly analysis.
<br /> Molybdenum L No No - Add parameter to sample suite for comparison between total and dissolved metals.
<br /> Silver µg/L Yes,Table 2 Yes,Table 1 4.7 0.17 Remove. Analyte is ND in 100%of surface water samples analytes in EPP(Whetstone,2016)and analyte is reported monthly for surface
<br /> water under the NOV/CDO(CDPHE,2011)Sample Suite.
<br /> Thallium µg/L Yes,Table 2 Yes,Table 1 none none Remove. Analyte is ND in 100%of surface water samples analytes in EPP(Whetstone,2016)and analyte is reported monthly for surface
<br /> water under the NOV/CDO(CDPHE,2011)Sample Suite.
<br /> Uranium µg/L No Table 1,Code 1,Code 3 4,115.95 2,570.93 Retain for quarterly analysis.
<br /> USEPA MCL=30 USEPA MCL=30
<br /> Zinc µ L Yes,Table 2 Yes,Table 1 249.51 188.98 Remove.Analyte is reported monthly for surface water under the NOV CDO CDPHE,2011 Sample Suite.
<br /> Radionuclides
<br /> Gross Alpha Ci/L Yes,Table 2 Yes,Table 1 none none Retain for quarterly analysis.
<br /> Gross Beta Ci/L Yes,Table 2 Yes,Table 1 none none Retain for quarterly analysis.
<br /> Radium-226,Total pCi/L Yes,Table 2 Yes,Code 3 none none Retain for quarterly analysis.
<br /> Radium-226,Dissolved pCi/L No Yes,Table3 and Code none none Retain for quarterly analysis.
<br /> Combined Radium(Radium Remove from analysis. Radium-226 reporting is captured with total and dissolved 226 analysis,radium-228 would be reported with gross
<br /> 226+228) pCi/L No Yes,Table 1 none none alpha analysis.
<br /> Additionally,analyte is reported for monthly surface water under the NOV CDO CDPHE,2011).
<br /> References:
<br /> Colorado department of Public Health and Environment(CDPHE). 2018. 5 CCR 1002-38,Regulation Number 38,Classification and Numeric Standards for South Platte Basin,Laramie River Basin,Republican River Basin,Smoky Hill River Basin,Appendix
<br /> 38-1:Stream Classifications and Water Quality Standards Tables. Water Quality Control Division. June.
<br /> CDPHE. 2011.Notice of Violation(NOV)/Cease and Desist Order(CDO),Number 10-100601-1.Water Quality Control Division. September.
<br /> Wheatstone Associates (Whetstone).2016. Schwartzwalder Mine,Environmental Protection Plan,Revision 1.0. Table 11-6 Comparison of Water Quality in Ralston Creek to Aquatic Toxicity Standards. September.
<br /> Notes:
<br /> Grey-shaded cells highlight analytes that are retained for quarterly analysis.
<br /> µg/L=micrograms per liter
<br /> EPP=Environmental Protection Plan,Technical Revision 11 (Wheatstone Associates,2016)
<br /> mg/L=milligrams per liter
<br /> ND =Non-detect
<br /> NOV/CDO=Notice of Violation/Cease and Desist Order(CDPHE,2011)
<br /> ORP=Oxidization Reduction Potential
<br /> pCi/L=picocuries per liter
<br /> USEPA MCL=United States Environmental Protection Agency Maximum Contaminant Level
<br /> PAGE 6 OF 22