performance modeling requirement was used to confirm the results for the final design system. The total <br />area for the final design system, including the 61VIN Pond, is 8.9 acres. With this final design area, the model <br />estimated an average 57% reduction in iron from 1.80 mg/L to 0.78 mg/L and a 20% sulfate reduction from <br />2520 mg/L to 2012 mg/L, thereby meeting the expected discharge targets outlined in Table 3. Although <br />pumping rates will fluctuate over the life of the mine dewatering activities, iron and sulfate targets are <br />expected to be achievable at minimum and maximum design flows. <br />Table 2-2: Basin Concentration Reduction Performance for the 357 gpm Design Dewatering Rate <br />Wetland Fe Rate Fe In Fe Out Sulfate Rate Sulfate Sulfate TDS Rate TDS In TDS Out <br />Basin Co �n t (mg/L) (mg/L) C(nsta t oin (mg/L) (mgt Consta t (mg/L) (mg/L) <br />Basin 1 45 1.80 1.37 5 2510 2436 2 5310 5241 <br />Basin 2 16 1.37 1.24 5 2436 2366 2 5241 5174 <br />Basin 3 16 1.24 1.13 5 2366 2304 2 5174 5114 <br />Basin 4 16 1.13 1.02 5 2304 2237 2 5114 5048 <br />Basin 5 12 1.02 0.78 5 2237 2012 2 5048 4811 <br />Total Fe Reduction: 57% Total Sulfate Reduction: 20% Total TDS Reduction: 9% <br />It is understood that the pumping rates will fluctuate over the life of the mine dewatering activities. <br />Despite this variation, iron and sulfate targets are still expected to be achievable at minimum design <br />flows. Lower flows provide additional retention time for solids settling and water processing, and <br />therefore, lower final concentrations. Table 4 provides a comparison of iron, sulfate and TDS reduction <br />at the maximum and minimum flowrate of 357 gpm and 75 gpm respectively. Although this design <br />provides suitable performance for iron and sulfate, the target TDS removal is not achievable with a <br />constructed wetland system. Options for TDS treatment have been discussed with Peabody and TDS <br />treatment will need achieved outside the scope of this project. <br />Table 2-3: Wetland Performance Comparison for Min/Max Design Dewatering Rates <br />Size Flow Rate Fe k Fe In Fe Out SO42- k SO42- In SO42- Out TDS k TDS in TDS out <br />(Acre) (gpm) (m/yr) (mg/L) (mg/L) (m/yr) (mg/L) (mg/L) (m/yr) (mg/L) (mg/L) <br />8.9 357 18 1.80 0.78 5 2510 2012 2 5310 4811 <br />8.9 75 18 1.80 0.07 5 2510 919 2 5310 3521 <br />PEABODY FINAL DESIGN TM 20181010 2.2 <br />COPYRIGHT 2012 BY CHZM H LL. INC. • COMPANY CONFIDENTIAL <br />