Laserfiche WebLink
REVISED <br />7/30/85 <br />determined from a nomograph of culvert discharge and diameter at <br />(head/diameter) = 1.0, as shown in Figure 2, Headwater Depth for CMP <br />Culverts With Inlet Control. Culverts are identified on Map 15, Fish <br />Creek Tipple Surface Facilities and Structures. Design parameters are <br />given in Table 6, Fish Creek Tipple 3 Culvert Design Specifications. <br />The designed culverts are installed with adequate fill cover and <br />compaction to prevent collapse. <br />