My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2018-09-07_REVISION - C1981010 (2)
DRMS
>
Day Forward
>
Revision
>
Coal
>
C1981010
>
2018-09-07_REVISION - C1981010 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2018 12:45:54 PM
Creation date
9/10/2018 9:19:24 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1981010
IBM Index Class Name
Revision
Doc Date
9/7/2018
Doc Name
Adequacy Review
From
Trapper Mining Inc
To
DRMS
Type & Sequence
PR9
Email Name
RAR
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Trapper Response to Comment 24: The pre -strip operation at Trapper Mine is currently removing <br />approximately 150 feet or more of overburden to the H seam east of active L pit. That material is being <br />hauled around to the west side of the L pit to be used for reclamation backfill. In October 2016, this section <br />at E 1,441,000 was pre -mining topography. Near the end of our 5 year permit term in 2022, this same <br />section would be near the open cut to Q seam, which represents approximately a 350 feet elevation <br />difference from the pre -mining topography. <br />25. For the Lancaster Pit, please provide the following cross sections <br />at: a. N402,000 <br />b. <br />N404,000 <br />C. <br />N406,000 <br />Trapper Response to Comment 25: The requested cross-sections are enclosed. <br />As per Rule 2.05.3(6)(b), plans must describe the geotechnical investigation associated <br />with the disposal area. After reviewing the proposed changes as well as the currently <br />approved Trapper PAP, DRMS was unable to locate any geotechnical investigation for the <br />proposed excess spoil area at the Utility Waste Disposal area. <br />26. Please provide results of a geotechnical investigation of the proposed disposal <br />site along the utility waste disposal area. <br />Trapper Response to Comment 26: Trapper does not consider the material hauled from N pit to the <br />Utility Waste Disposal Area as "Excess Spoil." Therefore, we feel that no geotechnical investigation is <br />warranted. <br />27. Please describe and provide a diagram of runoff routing and indicate the <br />receiving water body for runoff emanating from the utility waste disposal <br />area. <br />Trapper Response to Comment 27: With the additional material from N Pit that will be utilized to <br />create the "ridge feature" that appears on the M 12 Map, the water will be routed both north and south <br />of the proposed contours and will drain east into the Johnson Drainage Area, near Johnson #6 Pond. <br />This run-off will be routed through the existing constructed drainage in Johnson Gulch. <br />28. With respect to revised page 3-15a paragraph 6, please discuss why language <br />was removed regarding placement of spoil as a buttress to the North of K pit as <br />per AAI recommendation? It seems to be pertinent information to the <br />description of spoil disposal as per Rule 2.05.3 (6)b. <br />