My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2018-06-18_PERMIT FILE - C1982056A (4)
DRMS
>
Day Forward
>
Permit File
>
Coal
>
C1982056
>
2018-06-18_PERMIT FILE - C1982056A (4)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/17/2018 8:13:04 AM
Creation date
6/25/2018 6:55:51 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1982056A
IBM Index Class Name
Permit File
Doc Date
6/18/2018
Doc Name
Pages 2.05-65 to 2.05-197.3 part 2
Section_Exhibit Name
2.05 Operation and Reclamation Plans Part 2
Media Type
D
Archive
Yes
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
239
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Loadout Area Drainage Modifications (MR14-284) - The drainage and sediment controls for this area were <br />approved under an SAE, as referenced in the Permit text, however, given the configuration and type and level of <br />activities in this area, the existing drainage and sediment controls were found to be marginally adequate. The site <br />conditions were reviewed and evaluated, and the following changes, as shown on Figure EX49DD-F1, were <br />implemented to modify and upgrade the site drainage controls in order to be effective under all reasonably <br />anticipated conditions. <br />The pad area on the north side of the rail spur was reduced in size by removing the accumulation of coally material, <br />and regrading and reseeding part of this area, leaving only an access road along the north side of the spur. The <br />drainage configuration of the remaining pad was modified by filling a low area and placing a berm to direct all <br />drainage to the collection sump. The sump capacity and function were expanded by constructing a second sump in <br />series, removing accumulated sediment from the existing sump, and rebuilding the rock perimeter filter. The <br />control capacity of the rail spur collection ditch was increased by excavating several sediment traps in the ditch and <br />adding additional rock check dams. As a very limited disturbance area (approximately 1.2 acres) the Loadout area <br />disturbance meets the applicable criteria for a Small Area Exemption, the proposed drainage control measures should <br />be effective in controlling runoff and sedimentation, and construction of full-scale drainage and sediment control <br />structures is neither needed nor justified. <br />(5) Topsoil. A narrative explaining the method of removal and the amount to be removed and the plan for <br />storage_of topsoil, subsoil, and other material within the permit area subject to requirements of the topsoil removal <br />performance standards of 4.06.2. This narrative shall specify the depth of material to be salvaged from all disturbed <br />areas based on the soil information required by 2.04.9 and shall specify the volume of each type of material to be <br />salvaged. A map of any proposed storage structures shall accompany the narrative. The maps shall be prepared <br />according to the requirements of 2.10. <br />I;7xyEll eM0 <br />See response to 2.05.4, Reclamation Plan, below for details concerning the Foidel Creek Mine. TC does not propose to <br />disturb any additional land within the Fish Creek Tipple permit area. The Fish Creek Tipple and adjoining haulroad <br />were constructed prior to the promulgation of regulations mandating topsoil salvage and storage. Thus, the best <br />plant growth medium available is a mixture of spoil and soil materials which will be substituted for topsoil. This <br />situation is further discussed within the Fish Creek Tipple/Loadout Appendix, pages 2.04-36 through 2.04-38 and <br />pages 2.05-37 through 2.05-38 of Volume VIII. <br />Eastern Mining District Dewatering Facility - The Eastern Mining District Dewatering Facility will require <br />salvaging and stockpiling approximately 13,360 CY of topsoil from the access road and the facility site. During <br />upgrading of the road, approximately 3,600 CY of topsoil will be windrowed to the side of the road. The topsoil <br />along the length of the road is approximately 30 inches deep. The facility site will require salvaging and <br />stockpiling approximately 8,300 CY of topsoil. The topsoil from the site area is approximately 30 inches deep. A <br />test pit will be dug to verify the topsoil depth obtained from previous soil mapping work. The stockpiled topsoil, <br />which is located within the pad area, will be stabilized with the topsoil stockpile stabilizing seed mixture. <br />Additionally, approximately 6,295 CY of topsoil will be salvaged from the treatment pond site. This site has been <br />relocated closer to the road to facilitate delivery of chemicals. <br />Bleeder Fan - The bleeder fan facility will require salvaging and stockpiling approximately 4,700 CY of topsoil <br />from the access road and the facility site. During the upgrading of the road, approximately 2,800 CY of topsoil will <br />be windrowed to the side of the road and left in place. The 1,200 CY that will be salvaged from the road extension <br />will be placed in the stockpile that will be established on the fan pad. In addition to the topsoil stockpiled from the <br />road extension, approximately 740 CY will be salvaged and stockpiled from the pad. The soil resources <br />information was derived from information presented in Exhibits 7 and 8, Soil Profile Description and Soil Mapping <br />Unit Descriptions, Map No. 19, Mine No. 3, Soils presented in permit C-84-062. These materials are incorporated <br />herein by reference. At the bleeder fan site, TC will establish a test pit to verify topsoil depths prior to salvaging <br />topsoil. The stockpiled topsoil, which is located within the pad area, will be stabilized with the topsoil stockpile <br />stabilizing seed mixture. Prior to salvaging any topsoil from the site, a T & E species reconnaissance for Ute <br />Lady's Tresses, Spiranthes diuvialis, will be conducted, and the results forwarded to the Division. It is not <br />anticipated that this species will be found, as the site appears to be outside of its natural range. <br />TRI 8-90 2.05-84.12 04/05/18 <br />
The URL can be used to link to this page
Your browser does not support the video tag.