2018 GROUNDWATER MONITORING REPORT <br /> 4 CONCLUSIONS AND RECOMMENDATIONS <br /> ' Arcadis presents the following conclusions based on the information presented in this report: <br /> - For the March 2018 groundwater sampling event, concentrations of all analytes measured in the two <br /> ' downgradient wells, MW-7 and MW-13,were below the NPLs except for the total iron result for MW- <br /> 7. The concentration of total iron in monitoring well MW-7 was less than 10%over the NPL,thus no <br /> further actions at this time are necessary pursuant to the revised GMP. <br /> - Concentrations of TDS and sulfate are generally decreasing in MW-7 and generally stable in MW-13. <br /> - Generally stable or decreasing trends for manganese, dissolved iron, and potassium to sodium ratios <br /> continue to be observed in wells MW-7 and MW-13. <br /> - Groundwater flow is to the south and velocity is 0.3 foot to 2 feet per year,which is consistent with <br /> historical data. In addition, groundwater elevations and interpreted flow direction are similar to <br /> 1 previous sample rounds. <br /> Based on March 2018 sampling results that indicate there is no discernible impact from the CKD disposal <br /> area and that only one parameter(total iron)exceeded its NPL,Arcadis recommends that groundwater <br /> monitoring continue on an annual basis. <br />