Oar � <br /> LABORATORY, INC <br /> GCC Pueblo Edwin Olivares <br /> 3372 Lime Road Project Number: [none] <br /> Pueblo CO 81004 Project: Groundwater Monitoring <br /> Anions by EPA 300.0-Quality Control <br /> GEL Laboratories, LLC <br /> Reporting Spike Source %REC RPD <br /> Analyte Result Limit Units Level Result %REC Limits RPD Limit Notes <br /> Batch 1729949- <br /> BLANK(1203948038-BLK) Prepared: Analyzed:01/08/2018 <br /> Nitrite ND 0.100 mg/L - U <br /> Fluoride ND 0.100 - U <br /> LCS(1203948039-BKS) Prepared: Analyzed:01/08/2018 <br /> Fluoride 2.47 0.100 mg/L 2.50 98.7 90-110 <br /> Nitrite 2.38 0.100 112.50 95.1 90-110 <br /> DUP(1203948040 D) Source:441022001 Prepared: Analyzed:01/08/2018 <br /> Fluoride 0.859 1.00 mg/L 1.02 0-20 16.9 20 J <br /> Nitrite ND 1.00 <0.330 0-20 0 20 HU <br /> PS(1203948041 S) Source:441022001 Prepared: Analyzed:01/08/2018 <br /> Nitrite 24.3 1.00 mg/L 2.50 97.3 90-110 H <br /> Fluoride 25.4 1.00 2.50 97.6 90-110 <br /> Origins Laboratory, Inc. <br /> The results in this report apply to the samples analyzed in <br /> accordance with the chain of custody document. This <br /> analytical report must be reproduced in its entirety. <br /> Page 10 of 18 <br /> Jen Pellegrini,Project Manager <br />