Laserfiche WebLink
LI Qc!s4c.roup Analytical Report 14 <br /> Client: Cotter Corp <br /> Analyte: Chloride <br /> Prep Date: 12/16/2017 <br /> Analysis Date: 12/16/2017 <br /> Approved Method Source: 40 CFR 136.3 <br /> Prep ID: SM 4500-CI--1997 <br /> Analytical Method ID: SM 4500-Cl--1997 <br /> Instrument: Titrimetric <br /> Matrix: Aqueous(water,wastewater,groundwater) <br /> Sample volume used: 100 mL <br /> Analyst: SE <br /> Location ID SmpDate SCG# Results Flats RL Units <br /> MW-0 12/04/17 317849.A 20 2 mg/L <br /> Client: Cotter Corp <br /> Analyte: Sulfate,5042" <br /> Prep Date: 12/16/2017 <br /> Analysis Date: 12/16/2017 <br /> Approved Method Source: 40 CFR 136.3 <br /> Prep ID: ASTM D516-07 <br /> Analytical Method ID: ASTM D516-07 <br /> Instrument: Evo 160, UV/VIS <br /> Matrix: Aqueous(water,wastewater,groundwater) <br /> Sample volume used: 100 mL Dilution Factor: 10 <br /> Analyst: SE <br /> Location ID Smp Date SCG# Results Flats MDL RL Units <br /> MW-0 12/04/17 317849.A 148 1.2 5.9 mg/L <br /> Qualifiers. <br /> E—Extrapolated value.Value exceeds calibration range <br /> H—Analysis exceeded holding time <br /> J—Estimated value detected below the RL/MRL <br /> S—Spike recovery outside acceptance limits <br /> U—Analyte not detected <br /> X—See case narrative Confidential and Privileged 20-Dec-17 <br />