Laserfiche WebLink
November 16, 2017 C-1994-082/Yoast Mine JDM <br /> <br /> <br />Number of Partial Inspection this Fiscal Year: 3 <br />Number of Complete Inspections this Fiscal Year: 2 <br /> <br /> Page 2 of 6 <br /> <br /> <br />Inspection Topic Summary <br />NOTE: Y=Inspected N=Not Inspected R=Comments Noted V=Violation Issued NA=Not Applicable <br />Y - Air Resource Protection <br />R - Availability of Records <br />Y - Backfill & Grading <br />NA - Excess Spoil and Dev. Waste <br />NA - Explosives <br />Y - Fish & Wildlife <br />R - Hydrologic Balance <br />Y - Gen. Compliance With Mine Plan <br />R - Other <br />NA - Processing Waste <br /> <br />R - Roads <br />Y - Reclamation Success <br />Y - Revegetation <br />NA - Subsidence <br />R - Slides and Other Damage <br />Y - Support Facilities On-site <br />Y - Signs and Markers <br />NA - Support Facilities Not On-site <br />NA - Special Categories Of Mining <br />Y - Topsoil <br /> <br /> <br />COMMENTS <br /> <br />This inspection represents a complete coal inspection conducted by Jason Musick of the Division of Reclamation, <br />Mining, and Safety of the Seneca Yoast Mine. The weather was clear and the site was dry at the time of the <br />inspection. The site is a reclaimed surface mine currently in reclamation with no activities ongoing at the time of <br />the inspection. The Division is in the process of reviewing the RN-4 renewal appliaction and the SL-6 bond <br />release application. No activities were on-going at the site. <br />AVAILABILITY OF RECORDS – Rule 5.02.4(1): <br /> <br />Mine records were inspected at the Foidel Creek Mine office. Please see the Availability of Records section of <br />this report for additional information. <br /> <br />HYDROLOGIC BALANCE - Rule 4.05 Drainage Control 4.05.1, 4.05.2, 4.05.3; Siltation Structures 4.05.5, <br />4.05.6; Discharge Structures 4.05.7, 4.05.10; Diversions 4.05.4; Effluent Limits 4.05.2; Ground Water <br />Monitoring 4.05.13; Surface Water Monitoring 4.05.13; Drainage – Acid and Toxic Materials 4.05.8; <br />Impoundments 4.05.6, 4.05.9; Stream Buffer Zones 4.05.18: <br /> <br />Ponds 12 and 12A were holding water with Pond 12 discharging at the time of the inspection. Pond embankments <br />were stable and the primary spillways were functioning as designed with no issues noted with either the primary or <br />emergency spillways. <br />Pond 13 was stable with no discharge at the time of the inspection. Pond embankments were stable and the <br />primary and emergency spillways had no problems noted. <br />Pond 14 was frozen and stable with no discharge at the time of the inspection. No issues were noted with the <br />embankments and the primary discharge was functioning as designed. <br />Pond 010 was stable with no discharge at the time of the inspection. No issues were noted with the embankments <br />or spillways.