Permit Number 10GU1130 — AIRS Pt 021. Diesel -fired emergency backup generator to power the Shaft #2 <br />ventilation fan. The Initial Approval version of this permit was issued on March 24, 2010. The source completed <br />all initial approval permit condition requirements within the timeframes required, and these conditions were <br />addressed during the 2012 inspection. The source was issued a Final Approval version of the permit (Permit <br />IOGU1130 Issuance 2) on February 10, 2016. However, because the initial approval version was in effect at the <br />time of the inspection, that permit is used below for compliance determination purposes. There were no <br />substantial changes in the final version besides the removal of initial approval requirements. <br />1. This permit shall expire if the owner or operator of the source for which this permit was issued: (i) does <br />not commence construction/modification or operation of this source within 18 months after either the date <br />of issuance of this initial approval permit or the date on which such construction or activity was scheduled <br />to commence as set forth in the permit application associated with this permit; (ii) discontinues <br />construction for a period of eighteen months or more; or (iii) does not complete construction within a <br />reasonable time of the estimated completion date (See General Condition No. 6., Item 1.). Upon a <br />showing of good cause by the permittee, the Division may grant extensions of the permit. (Reference: <br />Regulation No. 3, Part B, Section III.F.4.) <br />According to the submitted Notice of Startup, the source began operating this unit on 4/5/2010, <br />shortly after permit issuance. Source is in compliance. <br />2. Within one hundred and eighty days (180) after commencement of operation, compliance with the <br />conditions contained on this permit shall be demonstrated to the Division. It is the permittee's <br />responsibility to self certify compliance with the conditions. Failure to demonstrate compliance within <br />180 days may result in revocation of the permit. (Information on how to certify compliance was mailed <br />with the permit.) <br />Appropriate self certification documents were received on 8/31/2010, within 180 days after <br />commencement of operation. Source is in compliance. <br />3. AIRS Point ID numbers (for example, "AIRS PT ID: 051/0015/021") shall be marked on the subject <br />equipment for ease of identification. (Reference: Regulation No. 3, Part B, Section III.E.) (State only <br />enforceable) <br />The AIRS Point ID is appropriately marked on the door of the unit. Source is in compliance. <br />4. Visible emissions shall not exceed twenty percent (20%) opacity during normal operation of the source. <br />During periods of startup, process modification, or adjustment of control equipment visible emissions <br />shall not exceed 30% opacity for more than six minutes in any sixty consecutive minutes. Opacity shall be <br />measured by EPA Method 9. (Reference: Regulation No. 1, Section II.A.1. & 4.) <br />The unit was not operating at the time of the inspection, and thus no visible emissions were <br />observed. Facility personnel reported that the unit does not smoke when operating. Without <br />evidence to suggest the contrary, the source is in compliance with this condition. <br />5. This source is subject to the odor requirements of Regulation No. 2. (State only enforceable) <br />No odors were observed during the inspection. Source is in compliance. <br />2015 Inspection Q <br />0510015-INSP-2015 Page 19 of 37 <br />