Laserfiche WebLink
GENERAL NOTES: WARNING: ABBREVIATION LEGEND: EXISTING SYMBOLS/LINES LEGEND: <br /> 1. PERFORM TRENCH EXCAVATION IN ACCORDANCE WITH OSHA REQUIREMENTS (REFER TO SECTION 02315). THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL APPROXIMATE MAJOR CONTOUR <br /> EXISTNG UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN ASSY ASSEMBLY <br /> 2. THE CONTRACTOR SHALL COMPLY WITH ALL REQUIREMENTS OF THE SOILS REPORT PREPARED FOR THIS MAINTAINING THEIR SERVICE AND/OR RELOCATION OF LINES. BFV BUTTERFLY VALVE MINOR CONTOUR <br /> PROJECT AND REVIEWED BY THE ENGINEER. THE CONTRACTOR SHALL CONTACT THE UTILITY NOTIFICATION CENTER OF COLORADO BY CIP CAST IRON PIPE FEMA 100 YR. FLOODPLAIN --•— •— <br /> n 3. TEMPORARY EROSION CONTROL MEASURES SHALL BE PROVIDED BY THE CONTRACTOR DURING CALLING 811, AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND CIPP CURED IN PLACE PIPE <br /> CONSTRUCTION. MAINTENANCE OF ONSITE DRAINAGE AND EROSION CONTROL FACILITIES DURING UTILITY LINES (E.G., BUT NOT LIMITED TO GAS LINES, WATER, ELECTRICITY WIRES, CABLES, CONC CONCRETE CONCRETE TRAIL _ _ — <br /> b CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES) BEFORE DIGGING. THE DIA DIAMETER DIRT ROAD <br /> CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE UNDERGROUND UTILITY LINES WHEN DIP DUCTILE IRON PIPE i <br /> 8 4. PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION,THE CONTRACTOR SHALL CONTACT ALL UTILITIES TO DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. E EAST JEEP/FOOT TRAIL _ <br /> COORDINATE SCHEDULES. <br /> COLORADO ELEV, EL ELEVATION FENCE ---i-- <br /> 5. THE TYPE, SIRE, LOCATION AND NUMBER ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE CALL BEFORE YOU DIG 8 EXEXISTING TREELINE <br /> WHEN SHOWN ON THESE CONSTRUCTION DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE �� FT FEET <br /> � FEET <br /> CONTRACTOR TO VERIFY THE EXISTENCE AND LOCATION OF ALL UNDERGROUND UTILITIES ALONG THE ID INSIDE DIAMETER RIPRAP <br /> ROUTE OF THE WORK PRIOR TO COMMENCING ANY NEW CONSTRUCTION. THE CONTRACTOR SHALL BE T--• `-1=` <br /> RESPONSIBLE OF ANY UNKNOWN UNDERGROUND UTILITIES. IN, ' INCH BUSH C' <br /> 6. THE CONTRACTOR SHALL MAINTAIN ONE (1) SET OF-REDUNED' PRINTS OF THE CONSTRUCTION REMOVAL NOTES: 'NV IINV RT DECIDUOUS TREE <br /> PLANS. THE'REDLINED'PRINTS SHALL BE KEPT CURRENT TO ACCURATELY REPRESENT THE DIMENSIONS CONIFEROUS TREE <br /> AND LOCATIONS OF ALL WORK PERFORMED BY THE CONTRACTOR. PRIOR TO FINAL PAYMENT,THE MIN MINIMUM <br /> 1. FEATURES NOT SPECIFICALLY IDENTIFIED ON PLAN FOR SALVAGE OR REMOVAL THAT CONFLICT WITH <br /> CONTRACTOR MUST PRESENT THE'REDLINED' PRINTS TO THE ENGINEER FOR PREPARATION OF A SET OF CONSTRUCTION ARE TO BE REVIEWED WITH ENGINEER. NAT NATURAL PHOTO CONTROL (XYZ) A <br /> REPRODUCIBLE'RECORD DRAWINGS'WHICH SHALL BE SUBMITTED TO THE OWNER WITHIN 30 DAYS OF NPT NATIONAL PIPE THREAD <br /> CONSTRUCTION ACCEPTANCE OF THE PROJECT BY THE OWNER. <br /> DEWATERING NOTES: OD OUTSIDE DIAMETER POWER POLES . . <br /> 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL REQUIRED CONSTRUCTION STAKING. THE PH POTHOLE POLE ANCHOR <br /> CONTRACTOR SHALL BE RESPONSIBLE FOR THE COST OF RE-SURVEYING REQUIRED DUE TO THE 1. CONTRACTOR SHOULD ANTICIPATE GROUNDWATER.A BID ITEM HAS BEEN PROVIDED FOR PVC POLYVINYL CHLORIDE <br /> CONTRACTOR'S OR SUBCONTRACTOR'S ACTIVITIES. DEWATERING AS ALL DEWATERING WORK NECESSARY FOR CONSTRUCTION. QTY QUANTITY LIGHT POLE <br /> B. THE CONTRACTOR SHALL PERFORM ALL WORK ACCORDING TO ALL OWNER, COUNTY, STATE AND FEDERAL 2. CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DEWATERING PLAN TO ENGINEER FOR REVIEW. N NORTH POST/POLE <br /> SAFETY AND HEALTH REGULATIONS. IN PARTICULAR,THE TRENCHING AND OPEN EXCAVATION OPERATIONS DEWATERING SHALL MEET ALL PERMIT REQUIREMENTS PRIOR TO STARTING ANY CONSTRUCTION S SOUTH <br /> SHALL COMPLY WITH ALL CURRENT O.S.HA. REGULATORY REQUIREMENTS. ACTIVITIES. SS STAINLESS STEEL SIGN - <br /> T.O.P. TOP OF PIPE FIRE HYDRANT <br /> 9 ALL FOR'ST RTRUCTION MWATER DISCTIVITIES HARGESMUST ASSOCIATEDYWITHH THE STATE CONS UCTIONFACTOLORADO PERMITTING NTY.* FOR IINFORMATIONCESS CONTACT TRAFFIC CONTROL NOTES: TYP TYPICAL <br /> W WEST <br /> MANHOLE <br /> THE CHERRY <br /> DRIVE DEPARTMENT OF HEALTH, WATER QUALITY CONTROL DIVISION.TS AND ENFO 4300 W 0 WITHOUT VALVE COVER <br /> CHERRY DRIVE SOUTH, DENVER, COLORADO, 80246-1530. ATTENTION: PERMITS AND ENFORCEMENT 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL CONSTRUCTION STAGING, ON OR / <br /> SECTION. PHONE (303) 692-3590. OFFSITE,AS NECESSARY TO COMPLETE THE WORK AS SPECIFIED IN THE PROJECT DOCUMENTS.A TRAFFIC SIGNAL <br /> STAGING PLAN SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW PRIOR TO ANY CONSTRUCTION <br /> 10. IF DEWATERING IS TO BE USED TO INSTALL UTILITIES, A STATE CONSTRUCTION DEWATERING DISCHARGE RELATED ACTIVITIES. R.R./CROSSWALK SIGNAL <br /> PERMIT IS REQUIRED IF DISCHARGE IS INTO A STORM SEWER,CHANNEL, IRRIGATION DITCH, OR ANY <br /> WATERS OF THE STATE OR THE UNITED STATES. OBTAINING THIS PERMIT IS THE RESPONSIBILITY OF THE MAIL BOX <br /> CONTRACTOR. EROSION CONTROL NOTES: METER <br /> 11. THE CONTRACTOR SHALL HAVE A REGISTERED LAND SURVEYOR TIE OUT AND RESET ANY PROPERTY <br /> CORNERS OR SECTION CORNERS PLANNED TO BE DISTURBED BY CONSTRUCTION OF THIS PROJECT AND 1. DISTURBANCE OF AREAS IDENTIFIED AS WETLANDS SHOULD BE AVOIDED IF POSSIBLE.CONTRACTOR UTILITY VAULT/BOX <br /> SHALL HAVE A REGISTERED LAND SURVEYOR REESTABLISH ANY PROPERTY CORNERS OR SECTION SHOULD COORDINATE INSTALLATION METHODS TO MINIMIZE DISTURBANCE. DISTURBANCE OF <br /> CORNERS INADVERTENTLY DISTURBED DURING CONSTRUCTION OF THIS PROJECT. WETLAND TO BE RESTORED TO A SATISFACTORY LEVEL AS DETERMINED BY USAGE AT c <br /> 12. ALL QUANTITIES ARE APPROXIMATE AND MAY VARY TO ALLOW COMPLETION Of WORK. CONTRACTOR'S EXPENSE. PROPOSED SYMBOLS/LINES LEGEND, <br /> 2. ADDITIONAL EROSION CONTROL MEASURES MAY BE REQUIRED DEPENDING ON INSTALLATION V <br /> 13. REVIEW ALL TREE REMOVALS WITH ENGINEER. METHODS. COORDINATE WITH ENGINEER. MAJOR CONTOUR 5000 <br /> 14. INSTALL AND MAINTAIN EROSION CONTROL DEVICES AS SPECIFIED OR AS DIRECTED BY ENGINEER. MINOR CONTOUR -- <br /> 15. DISTURBED TURF AREAS TO BE SEEDED WITH SEED MIX IDENTIFIED IN THE SPECIFICATIONS (SECTION WORKING WITHIN FLOODWAY: WATER PIPE (SIZE AS SHOWN) <br /> 02900). 1. THE PROJECT SITE IS LOCATED NEAR A DESIGNATED FLOODWAY. NO UNAUTHORIZED FILL SHALL WATER VALVE IM <br /> 16. CONTRACTOR SHALL STRIP, SALVAGE,AND RESPREAD EXISTING TOPSOIL BE PLACED AND ALL CONSTRUCTION MATERIALS, EROSION CONTROL MATERIALS, ETC SHALL BE RIPRAP <br /> REMOVED AFTER CONSTRUCTION. <br /> TREE PROTECTION STANDARDS: <br /> 1. PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING <br /> TREES WITH SUCH BARRIERS TO BE Of ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, <br /> SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF(%) <br /> OF THE DRIP LINE, WHICHEVER IS GREATER. THE SPACING OF STAKES SHALL BE TEN (10) FEET.THERE <br /> SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS,OR FILL WITHIN THE FENCED <br /> —--TREE PROTECTION ZONE. <br /> 2. DURING THE CONSTRUCTION STAGE OF DEVELOPMENT,THE APPLICANT SHALL PREVENT THE CLEANING OF <br /> EQUIPMENT OR MATERIAL OR THE STORAGE OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, <br /> ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE.WITHIN <br /> THE BARRIERS OF ANY PROTECTED TREE OR GROUP OF TREES. <br /> 3. NO DAMAGING ATTACHMENT, WIRES,SIGNS, OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. <br /> RECEIVED <br /> SEP 1 3 2(117 <br /> DIVII&ON OF RFLL.UATM DBC REVIEW COMMENTS <br /> LONING AND SAFETY 8/21/2017 <br /> s M-1982-147 TR05 <br /> e <br /> .. SUB CONSULTANT PRIME CONSULTANT PROJECT TITLE SHEET TITLE <br /> t*swwAw MANN LAKES FRENCH DRAIN PROJECT <br /> 33 RAL NOTES AND LEGEND <br /> esuxiares t„c. GENE <br /> g OWN BY CHK'D APP'D DWG DATE 9 S 1 7 <br /> tU W®k477n� DJW RDD ISCALE <br /> Responsive partner,Exceptional outcomes PROJECT NO. SHEET NO. REV N0. <br /> 9 RE•d REVISION DESCRIPTION DWN APP REV DATE 4025 AUTOMATION WAY, BLDG E (PHONE):970-223-4705 COTCMD101 G-002 <br /> N FORT COLLINS. CO. 80525 (FAX).970-223-4706 <br />