Laserfiche WebLink
Laboratories, Inc. -- -- <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 <br /> Lewicki &Associates ACZ Project 1D. L37726 <br /> L37726-01 NG426309 Acid Generation Potential(talc) M600/2-78-054 1 3 N1 See Case Narrative <br /> Acid Neutralization Potential(talc) M600/2-78-054 1 3 N1 See Case Narrative. <br /> Acid-Base Potential(talc) M600/2-78-054 1.3 N1 See Case Narrative <br /> WG426040 Aluminum total(3050) M6010B ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> ING426215 Boron,total(3050) M60108 ICP 61 Target analyte detected in prep/method blank at or above <br /> the method reporting limit See Case Narrative <br /> M60108 ICP M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable <br /> M60108 ICP ZG The ICP or ICP-MS Serial Dilution was not used for data <br /> validation because the sample concentration was less than <br /> 50 times the MDL. <br /> WG426134 Carbon,total(TO) ASA No 9 29-Z2 4 CombustiONIR Q6 Sample was received above recommended temperature <br /> ASA No.9 29-2 2.4 Combustion/IR RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> Carbon,total inorganic(TIC) ASA No.9 29-2 2.4(talc TO- Q6 Sample was received above recommended temperature. <br /> TOO) <br /> ASA No.9 29-2.2.4(talc TO- RA Relative Percent Difference(RPD)was not used for data <br /> TOC) validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> ASA No.9 29-2 2 4(talc TO- ZQ Analyte was not evaluated in the laboratory control <br /> TOC) standard. Either the analyte is not inducted in the scope of <br /> the analytical method or a commercial standard containing <br /> the analyte is not available <br /> Carbon,total organic(TOC) ASA No 9 29-2 2 4 Combustion/iR Q6 Sample was received above recommended temperature <br /> ASA No 9 29-2.2 4 Combustion/lR RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL), <br /> ASA No 9 29-2 2.4 CombustionrlR ZQ Analyte was not evaluated in the laboratory control <br /> standard. Either the analyte is not included in the scope of <br /> the analytical method or a commercial standard containing <br /> the analyte is not available <br /> WG426040 Cobalt total(3050) M6010B ICP ZG The ICP or ICP-MS Serial Dilution was not used for data <br /> validation because the sample concentration was less than <br /> 50 times the MDL <br /> WG426215 Copper total(3050) M6010B ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportonate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable <br /> VIJG426142 Iron,total(3050) M6010B ICP N13 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> WG426215 Lead,total(3050) M60106 ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> Manganese,total(3050) M6010B ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable <br /> WG425510 Mercury total M7471A CVAA Q6 Sample was received above recommended temperature <br /> WG426040 Molybdenum.total(3050) N16010B ICP ZG The ICP or ICP-MS Serial Dilution was not used for data <br /> validation because the sample concentration was less than <br /> 50 times the MDL <br /> Phosphorus total(3050) M60106 ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable <br /> WG426099 Sulfur Organic Residual M600/2-78-054 3 2 4-MOD RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> Sulfur Sulfate M600/2-78-054 3 2 n-MOD R1 RPD exceeded the method or laboratory acceptance limit <br /> REPAD.15.06.05.01 <br /> L37726-1707261644 Pine 14 c4: 10 <br />