APPENDIX U <br />Tasks <br />TEST METHOD <br />TEST FREQUENCY <br />Appropriate Part <br />Grab Tensile Strength and <br />Elongation <br />ASTM D4632 <br />" <br />Trapezoidal Tear Strength <br />ASTM D 4533 <br />" <br />Puncture Strength <br />ASTM D4833 <br />" <br />Permittivity <br />ASTM D4491 <br />" <br />Apparent Opening Size <br />ASTM D4751 <br />" <br />UV Stability <br />ASTM D4355 <br />" <br />Geocom osite <br />Transmissivity <br />ASTM D4716 <br />1 test per 100,000 ft and minimum <br />1 test per lot(4) <br />Ply Adhesion <br />ASTM D6636 <br />" <br />Soil Drainage <br />Layers CQA <br />Soil Drainage Layer <br />Potential Borrow <br />Source <br />Grain Size <br />ASTM D422 <br />1 per 2620 yd <br />Hydraulic Conductivity <br />ASTM D2434 <br />1 per 2620 yd <br />Carbonate Content <br />ASTM D4373 soils <br />1 per 2620 yd <br />Carbonate Content <br />ASTM D3042 <br />(aggregates) <br />1 per 2620 yd <br />Soil Drainage Layer <br />After Placement <br />Grain Size <br />ASTM D422 <br />1 each hectare 4000 d area <br />Hydraulic Conductivity <br />ASTM D2434 <br />1 each 3 hectares 12000 d area <br />Carbonate Content <br />ASTM D4373 soils <br />1 per 2620 d <br />Carbonate Content(2)ASTM <br />D3042 <br />(aggregates) <br />1 per 2620 yd <br />Low <br />Permeability <br />Liner <br />Construction <br />PR -02 10/12 <br />