My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-05-12_PERMIT FILE - C2010089 (3)
DRMS
>
Day Forward
>
Permit File
>
Coal
>
C2010089
>
2017-05-12_PERMIT FILE - C2010089 (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/31/2017 7:42:17 AM
Creation date
5/31/2017 7:38:27 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C2010089
IBM Index Class Name
PERMIT FILE
Doc Date
5/12/2017
Doc Name
SECAD Runs for Culverts
Section_Exhibit Name
Appendix 2.05.3(3)-1
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SEDCAD 4 for Windows <br />r'—,rinht 100A -9(110 P-1. 1 Crhui�h <br />Structure #1 (Cu/vert) <br />NHN CUL VERT C-1 <br />Culvert Inputs: <br />Culvert Results: <br />Structure Detail; <br />Max. Entrance <br />Length (ft) Slope (%) Manning's n Headwater Tailwater (ft) Loss Coef. <br />(ft) (Ke) <br />40.00 2.50 0.0150 2.10 0.00 0.70 <br />Design Discharge = 8.80 cfs <br />Minimum pipe diameter: 1 - 18 inch pipe(s) required <br />y <br />Filename: CULVERT C-1 10YR-24HR_02.06.17.sc4 Printed 02-06-2017 <br />Appendix 2.05.3(3)-1 Page 5 February 2017 (TR -15) <br />
The URL can be used to link to this page
Your browser does not support the video tag.