Laserfiche WebLink
as described in the text of each sedimentation pond's design report. All sediment ponds are <br />designed and located to capture surface runoff from upstream disturbance areas and to comply <br />with all applicable State and Federal regulations. <br />With regards to Pond 007, it is currently over -designed for its watershed area. Originally, the <br />watershed area was calculated to be approximately 514 acres (see Map 2.05.3(3)-2-2), and the <br />pond was built in 1995 using that value. Pond 008 was permitted in 1999 and built in 2000 in the <br />western portion of the Pond 007 watershed. The Pond 008 drainage area directly subtracts from <br />the original Pond 007 watershed, so the Pond 007 watershed has been reduced to about 423 <br />acres. Because of this significant reduction in area (17.7%), new run-off calculations for Pond <br />007 were not done. <br />Section 2.05.3(3) Page 8 February 2017 (TR -78) <br />