My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-02-28_REPORT - C1981028 (29)
DRMS
>
Day Forward
>
Report
>
Coal
>
C1981028
>
2017-02-28_REPORT - C1981028 (29)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/29/2017 8:17:18 AM
Creation date
3/1/2017 6:39:18 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1981028
IBM Index Class Name
Report
Doc Date
2/28/2017
Doc Name
Annual Hydrology Report
From
Coors Energy Company
To
DRMS
Annual Report Year
2016
Permit Index Doc Type
Hydrology Report
Email Name
RAR
DIH
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
173
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Case Narrative <br />Client: Coors Energy Company <br />Project/Site: Coors - Keenesburg Mine, CO Quarterly <br />Job ID: 280-82370-1 <br />Laboratory: TestAmerica Denver <br />Narrative <br />TestAmerica Job ID: 280-82370-1 <br />L41 <br />CASE NARRATIVE <br />Client: Coors Energy Company <br />Project: Coors - Keenesburg Mine, CO Quarterly <br />Report Number: 280-82370-1 <br />With the exceptions noted as flags or footnotes, standard analytical protocols were followed in the analysis of the samples and no <br />problems were encountered or anomalies observed. In addition all laboratory quality control samples were within established control <br />limits, with any exceptions noted below. Each sample was analyzed to achieve the lowest possible reporting limit within the constraints of <br />the method. In some cases, due to interference or analytes present at high concentrations, samples were diluted. For diluted samples, <br />the reporting limits are adjusted relative to the dilution required. <br />Calculations are performed before rounding to avoid round -off errors in calculated results. <br />All holding times were met and proper preservation noted for the methods performed on these samples, unless otherwise detailed in the <br />individual sections below. <br />RECEIPT <br />The samples were received on 4/25/2016 9:55 AM; the samples arrived in good condition, properly preserved and, where required, on ice. <br />The temperature of the cooler at receipt was 1.3° C. <br />The sample IDs on the container labels received for all samples do not match the information on the chain of custody. The sample IDs on <br />the container labels list a "-B" suffix in addition to the sample ID listed on the chain of custody. The laboratory logged all sample IDs per <br />the chain of custody and will proceed unless instructed otherwise. The client was notified on 4/25/2016. <br />The chain of custody does not indicate a sample matrix type for any of the sample IDs listed on the chain of custody. The laboratory logged <br />the samples as aqueous/water matrix per the physical characteristics of the sample volume received. <br />The sample collection time listed on the container label for sample SMW-2 (280-82370-6) does not match the information on the chain of <br />custody. The sample collection time on the container is listed as "9:02A" while the chain of custody lists "9:50A". The laboratory logged the <br />sample collection time per the chain of custody and will proceed unless instructed otherwise. The client was notified on 4/25/2016. <br />DISSOLVED METALS (ICP) <br />The MS/MSD performed on sample SMW-2 (280-82370-6) exhibited spike recoveries outside QC control limits for several analytes. The <br />associated LCS was in control and demonstrates that operating procedures were in control. No further action was required. <br />The instrument blank for analytical batch 280-324566 contained Calcium at concentrations greater than the reporting limit (RL); the <br />associated samples were not re -analyzed as they contained concentrations greater than 10x those present in the blank; therefore, <br />corrective action was deemed unnecessary. <br />No additional analytical or quality issues were noted, other than those described above or in the Definitions/Glossary page. <br />SODIUM ABSORPTION RATIO <br />No analytical or quality issues were noted, other than those described above or in the Definitions/Glossary page. <br />ALKALINITY <br />The method duplicate associated with batch 280-323866 exhibited RPD data outside QC control limits for Alkalinity. The associated <br />LCS/LCSD was in control and demonstrates that operating procedures were in control. No further action was required. <br />No additional analytical or quality issues were noted, other than those described above or in the Definitions/Glossary page. <br />SPECIFIC CONDUCTIVITY <br />No analytical or quality issues were noted, other than those described above or in the Definitions/Glossary page. <br />TOTAL DISSOLVED SOLIDS <br />TestAmerica Denver <br />Page 4 of 32 5/12/2016 <br />
The URL can be used to link to this page
Your browser does not support the video tag.