Laserfiche WebLink
F*+ Freedom <br />.�INDUSTRIES <br />MATERIAL SAFETY DATA SHEET <br />EnviroFloc CF -1 <br />Preparation date: April 26, 2011 <br />Page 2 of 7 <br />SECTION 2 - HAZARDS IDENTIFICATION (continued) <br />INHALATION (breathing): <br />Spray or mist can cause sore throat and irritation, which may be severe. <br />CHRONIC EFFECTS/CARCINOGENICITY: <br />This product (or component) is not listed in IARC Monographs, the current NTP <br />Report on Carcinogens or the ACGIH TLVs as a carcinogen or potential <br />carcinogen. OSHA does not regulate it as a carcinogen. <br />SECTION 3 - COMPOSITION / INFORMATION ON INGREDIENTS <br />Component % CAS No. <br />Polyaluminum hydroxychlorosulfate 15-40 Proprietary <br />Water 60-85 7732-18-5 <br />SECTION 4 - FIRST AID MEASURES <br />EYE CONTACT: <br />Immediately flush with large amounts of water for at least 15 minutes, lifting upper <br />and lower lids occasionally. Get immediate medical attention. Do not use <br />chemical antidote. <br />SKIN CONTACT: <br />Immediately flush exposed area with water for at least 15 minutes, then wash with <br />soap and water. If reddening persists, or if open sores or blisters develop, see a <br />physician. Remove contaminated clothing and launder before re -use. <br />INGESTION (swallowing): <br />If conscious, immediately give two large glasses of milk, if available, or water. <br />Never give anything by mouth to an unconscious person. Do not induce <br />vomiting; vomiting may further damage the mouth and throat. Call a physician. <br />INHALATION (breathing): <br />Immediately move to fresh air. If breathing has stopped, give artificial respiration. <br />Get immediate medical attention. <br />