ACZ Laboratories, Inc. = • <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 - • • <br /> Golder Associates ACZ Project ID: L32402 <br /> I .. <br /> L32402-01 WG408637 Sodium,dissolved M200.7 ICP MA Recovery for either the spike or spike duplicate was outside <br /> of the acceptance limits;the RPD was within the <br /> acceptance limits. <br /> WG408382 Chloride M300.0-Ion Chromatography DC Sample required dilution. Non-target analyte exceeded <br /> calibration range. <br /> M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> L32402-02 WG408637 Sodium,dissolved M200.7 ICP MA Recovery for either the spike or spike duplicate was outside <br /> of the acceptance limits;the RPD was within the <br /> acceptance limits. <br /> WG408382 Chloride M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> Sulfate M300.0-Ion Chromatography DC Sample required dilution. Non-target analyze exceeded <br /> calibration range. <br /> L32402-03 WG408637 Sodium,dissolved M200.7 ICP MA Recovery for either the spike or spike duplicate was outside <br /> I of the acceptance limits;the RPD was within the <br /> acceptance limits. <br /> WG408382 Chloride M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> Sulfate M300.0-Ion Chromatography DC Sample required dilution. Non-target analyte exceeded <br /> calibration range. <br /> L32402-04 WG408382 Chloride M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> Sulfate M300.0-Ion Chromatography DC Sample required dilution. Non-target analyte exceeded <br /> calibration range. <br /> L32402-05 WG408382 Chloride M300.0-Ion Chromatography DC Sample required dilution. Non-target analyte exceeded <br /> calibration range. <br /> M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG408467 pH SM4500H+B ZW Method deviation. The sample was centrifuged prior to <br /> analysis due to high solid content. <br /> Total Alkalinity SM2320B-Titration ZW Method deviation. The sample was centrifuged prior to <br /> analysis due to high solid content. <br /> L32402-06 WG4011382 Chloride M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG408494 pH SM4500H+B ZW Method deviation. The sample was centrifuged prior to <br /> analysis due to high solid content. <br /> WG408382 Sulfate M300.0-Ion Chromatography DC Sample required dilution. Non-target analyte exceeded <br /> calibration range. <br /> WG408494 Total Alkalinity SM2320B-Titration ZW Method deviation. The sample was centrifuged prior to <br /> analysis due to high solid content. <br /> L32402-07 WG408382 Chloride M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG408494 pH SM4500H+B ZW Method deviation. The sample was centrifuged prior to <br /> analysis due to high solid content. <br /> WG408382 Sulfate M300.0-Ion Chromatography DC Sample required dilution. Non-target analyte exceeded <br /> calibration range. <br /> WG408494 Total Alkalinity SM2320B-Titration ZW Method deviation. The sample was centrifuged prior to <br /> analysis due to high solid content. <br /> L32402-08 WG408382 Chloride M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> REPAD.15.06.05.01 <br /> L32402-1608291051 Page 16 of 21 <br />