Laserfiche WebLink
Structure <br />Structure: <br />MR -418 Calculations <br />C5E-7 - 30" HDPE - Stand Alone #1 <br />Manning's Coefficient (n) 0.024 <br />Inside Diameter (in) <br />24.3 <br />Radius (in) <br />12.15 <br />Area (ft) <br />3.22 <br />Hydraulic Radius (ft.) <br />0.51 <br />Slope (ft./ft.) <br />0.05 <br />Maximum Flow (cfs) 28.38 <br />Design Discharge (cfs) 13.7 <br />Combined Flow 16.45 <br />(C5E-7 Design Flow + C5E-25 Design Flow) <br />Maximum Flow > Combined Flow? Yes <br />D5E-4 - #6 <br />Maximum Flow (cfs) 38.82 <br />Design Discharge (cfs) 15.95 <br />Combined Flow 18.70 <br />(D5E-4 Design Flow + C5E-25 Design Flow) <br />Maximum Flow > Combined Flow? Yes <br />2 of 5 <br />8/23/2016 <br />w/ Freeboard <br />(ft.) <br />Manning's Coefficient (n) <br />0.017 <br />Top Width (T) <br />4.21 <br />Bottom Width (b) <br />0.00 <br />Depth (h) <br />1.05 <br />z (ft.) <br />2.00 <br />Area (ft) <br />2.21 <br />Wetted Perimeter (ft.) <br />4.70 <br />Hydraulic Radius (ft.) <br />0.47 <br />Slope (ft./ft.) <br />0.11 <br />Maximum Flow (cfs) 38.82 <br />Design Discharge (cfs) 15.95 <br />Combined Flow 18.70 <br />(D5E-4 Design Flow + C5E-25 Design Flow) <br />Maximum Flow > Combined Flow? Yes <br />2 of 5 <br />8/23/2016 <br />