Laserfiche WebLink
YES NO N/A <br />1 x <br />2 x <br />3 x <br />4 x <br />5 <br />x <br />x <br />x <br />x <br />x <br />x <br />7 x <br />8 x <br />9 x <br />10 x <br />11 x <br />12 x <br />13 x <br />14 <br />15 <br />16 x <br />17 x <br />x <br />x <br />x <br />x <br />x <br />20 x <br />21 <br />"Boils" beneath stream or ponded water: <br />Foundation preparation (removal of vegetation, stumps, topsoil: <br />Lift thickness: <br />Compaction according to approved plan: <br />Burning (specify extent and location): <br />Angle of slope:           upstream,              downstream  <br />From underdrain pipes <br />At isolated points on embanckement slopes <br />At natural hillside: <br />Over widespread areas: <br />From downstream foundation area: <br />Existing embankment freeboard = NA <br />Cracks or scarps on crest: <br />Cracks or scarps on slope: <br />Sloughing or bulging on slope: <br />*Major erosion problems: <br />Surface movements in valley bottom or on hillside: <br />*Erosion of toe: <br />*Major adverse changes in these items could cause instability and should be reported to the Engineering Manager  <br />and Mine Superintendent for further evaluation.  Adverse conditions noted in these items should normally be  <br />described (extextent, location, volume, etc.) here: None <br />6 <br />PERIODIC INSPECTION FORM:  Water, Sediment, or Slurry Impoundments <br />INSPECTOR'S NAME:   Jason Herden            <br />Total =  N/A   <br />MINE NAME: Peabody Sage Creek Mine   <br />MINE I.D. NO.: CMLRD Permit No. C‐2009‐087   <br />FACILITY CONFIGURATION: Incised Pond  <br />DATE: 05/03/16 <br />DATE LAST INSPECTION: 03/04/16 <br />LOCATION: NW¼ NE¼, Sec. 2, T5N, R87W <br />LOCATION: 7.1 mi. SE of Hayden, CO   <br />OWNER'S REP.: Brian Watterson    <br />Trash racks clear and in place: <br />Discharge rate (gpm) = 1126 <br />     Spillway channels and pipes: <br />Visible sumps or sinkholes in slurry surface: <br />18 <br />19 <br />NPDES I.D. NO.:   CO‐0048275 D.P. 002      <br />*Clogging <br />*Seepage (specify location, color, and approximate volume) <br />*Cracking or crushing of pipes <br />SITE NAME: Wadge Impoundment #002     <br />CIRCLE OR WRITE IN APPROPRIATE RESPONSE: <br />     Decant system: <br />     Diversion ditches: <br />     Spillway pipes: <br />     Decant system: <br />*Water impounded against toe: <br />Cracks, bulging, or erosion on upstream face: <br />         Increase             Decrease in water level:   NO CHANGE