Laserfiche WebLink
® Trust our People.Trust our Data. Billings,MT 800.735.4489•Casper,WY 888.235.0515 <br /> n www.energylab.com College Station,TX 888.690.2218•Gillette.WY 866.686.7175•Helena.MT 877.472.0711 <br /> QA/QC Summary Report <br /> Prepared by Casper, WY Branch <br /> Client: Energy Fuels Resources(USA) Inc Report Date: 06/29/16 <br /> Project: Whirlwind Annual Sampling 2016 Work Order: C16060138 <br /> 1 <br /> Analyte Count Result Units RL %REC Low Limit High Limit RPD RPDLimit Qual <br /> i <br /> Method: A4500-F C Analytical Run: MANTECH_160606A <br /> Lab ID: CCV-9047 Continuing Calibration Verification Standard 06/06/16 11:43 <br /> Fluoride 2.00 mg/L 0.10 100 90 110 <br /> Method: A4500-F C Batch: R212334 <br /> Lab ID: MBLK Method Blank Run: MANTECH 160606A 06/06/16 11:38 <br /> Fluoride ND mg/L 0.09 <br /> Lab ID: LCS-9086 Laboratory Control Sample Run:MANTECH_160606A 06/06/16 11:41 <br /> Fluoride 1.92 mg/L 0.10 96 90 110 <br /> Lab ID: C16060138-001BMS Sample Matrix Spike Run: MANTECH_160606A 06/06/16 11:56 <br /> Fluoride 2.12 mg/L 0.10 94 80 120 <br /> Lab ID: C16060138-001BMSD Sample Matrix Spike Duplicate Run: MANTECH_160606A 06/06/16 11:59 <br /> Fluoride 2.12 mg/L 0.10 94 80 120 0.0 10 <br /> Qualifiers: <br /> RL-Analyte reporting limit. ND-Not detected at the reporting limit. <br /> MDC-Minimum detectable concentration <br /> Page 16 of 31 <br />